2002
DOI: 10.1016/s0002-8703(02)00065-0
|View full text |Cite
|
Sign up to set email alerts
|

Common electrocardiographic artifacts mimicking arrhythmias in ambulatory monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
7
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…These are nonpolarizable electrode types, with a silver-silver chloride (AgCl) element coated with an ionically active gel. Polarizable silver textrodes (textile electrodes) embedded in the shirt/vest carrier are also now available (Lobodzinski & Laks, 2008;Perez de Isla et al, 2011 (Keller & Lemberg, 2007;Knight et al, 1999Knight et al, , 2001Krasnow & Bloomfield, 1976;Márquez, Colín, Guevara, Iturralde, & Hermosillo, 2002).…”
Section: Electrodes For Aecg Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…These are nonpolarizable electrode types, with a silver-silver chloride (AgCl) element coated with an ionically active gel. Polarizable silver textrodes (textile electrodes) embedded in the shirt/vest carrier are also now available (Lobodzinski & Laks, 2008;Perez de Isla et al, 2011 (Keller & Lemberg, 2007;Knight et al, 1999Knight et al, , 2001Krasnow & Bloomfield, 1976;Márquez, Colín, Guevara, Iturralde, & Hermosillo, 2002).…”
Section: Electrodes For Aecg Applicationsmentioning
confidence: 99%
“…A second group of artifacts is probably related to intermittent impairment of electrode contact or recorder problems in older recording systems that can result in tape slowing or intermittent stoppage (Krasnow & Bloomfield, 1976;Márquez et al, 2002). These artifacts result in pseudo-pauses that can simulate sinus arrest, pacemaker malfunction, or high-degree atrioventricular conduction block.…”
Section: Aecg Analysis and Interpretationmentioning
confidence: 99%
“…Also the patient confi rmed that he had been working in the base station during abnormal records. The most likely cause of the ECG artifact was the infl uence of electromagnetic interference on holter monitoring in the base station [1] . An ECG artifact can closely simulate VT, and physicians should include it in their differential diagnosis of wide complex tachycardias to minimize unneeded procedures [2] .…”
Section: Correspondencementioning
confidence: 99%
“…Koşuyolu Heart Journal 2016;19 (1) Figure 1). Therefore, the patient was referred to our hospital for an electrophysiological study.…”
mentioning
confidence: 99%
“…Current ECG-monitoring systems are vulnerable to misinterpretation of pseudoarrhythmias, movement and nursing-manipulation artifacts or even hiccups. 9 We evaluated validity of standard automated arrhythmia detection in patients with stroke during Stroke Unit ECG monitoring.…”
mentioning