2012
DOI: 10.1007/s00340-012-4908-x
|View full text |Cite
|
Sign up to set email alerts
|

Compact QEPAS sensor for trace methane and ammonia detection in impure hydrogen

Abstract: Abstract.A compact two-gas sensor based on quartz enhanced photoacoustic spectroscopy (QEPAS) was developed for trace methane and ammonia quantification in impure hydrogen. The sensor is equipped with a micro-resonator to confine the sound wave and enhance QEPAS signal.The normalized noise-equivalent absorption coefficients (1σ)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
37
1

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 70 publications
(38 citation statements)
references
References 21 publications
0
37
1
Order By: Relevance
“…The signal-to-noise ratios (SNRs) of the two methods were calculated separately since the sensitivity is determined by the SNR. With the general QEPAS method, it was verified in several experimental tests [4,13,14] that the observed QEPAS noise is equal to the theoretical thermal noise of the QTF at its resonance frequency. In this work, the theoretical and experimental thermal noise levels are 420.3 cnts and 450.2 cnts, The normalized noise-equivalent absorption coefficient is 3.3×10 −7 cm −1 ·W·Hz −1/2 .…”
Section: Resultsmentioning
confidence: 96%
“…The signal-to-noise ratios (SNRs) of the two methods were calculated separately since the sensitivity is determined by the SNR. With the general QEPAS method, it was verified in several experimental tests [4,13,14] that the observed QEPAS noise is equal to the theoretical thermal noise of the QTF at its resonance frequency. In this work, the theoretical and experimental thermal noise levels are 420.3 cnts and 450.2 cnts, The normalized noise-equivalent absorption coefficient is 3.3×10 −7 cm −1 ·W·Hz −1/2 .…”
Section: Resultsmentioning
confidence: 96%
“…The signal from the fork was passed through another lock in the amplifier and was delivered to a data acquisition card (Adlink PCI9826), and then connected to a personal computer. The photoacoustic signal received by the detector [7] is : ε αQ…”
Section: Experiments and Resultsmentioning
confidence: 99%
“…Also the surrounding gas mixture, e.g. humidity 4 influences the signal by promoting or delaying deexcitation and vibrational-translational-transfer. Figure 1.…”
Section: Introductionmentioning
confidence: 99%