2005
DOI: 10.4067/s0365-28072005000200010
|View full text |Cite
|
Sign up to set email alerts
|

Comparación de Metodologías de Cálculo de Propiedades Hidráulicas de un Suelo a Partir de Datos Medidos con Infiltrómetro de Disco

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
2
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 0 publications
1
2
0
1
Order By: Relevance
“…The locations of the field tests are shown in Figure 2A, while Figure 3 shows the map with the reclassified data according to Table 1. The values of the magnitude of the soil parameters are similar to Aoki and Sereno (2005) and White and Sully (1987), who worked with pressure 1 cm in a loam soil, obtaining values of hydraulic conductivity (Ko) of 12.6 m h -1 ). Smettem et al (1994), estimated a Ko of 56 mm h -1 using a sandy loam soil, with a water application pressure of 2 cm.…”
Section: Resultssupporting
confidence: 70%
See 2 more Smart Citations
“…The locations of the field tests are shown in Figure 2A, while Figure 3 shows the map with the reclassified data according to Table 1. The values of the magnitude of the soil parameters are similar to Aoki and Sereno (2005) and White and Sully (1987), who worked with pressure 1 cm in a loam soil, obtaining values of hydraulic conductivity (Ko) of 12.6 m h -1 ). Smettem et al (1994), estimated a Ko of 56 mm h -1 using a sandy loam soil, with a water application pressure of 2 cm.…”
Section: Resultssupporting
confidence: 70%
“…Metodología de clasificación de la permeabilidad (Cisneros, 2001). We collected infiltration information by using a minidisc portable tension infiltrometer, The minidisk allows the quantitative identification of the relative contribution of the key hydrodynamic parameters that depend on the flow of infiltrated water and pressure during the water application, which is the unsaturated hydraulic conductivity (Angulo-Jaramillo et al, 2000;Aoki & Sereno, 2005;Wilson & Luxmoore, 1988). The infiltrometer is fixed to the ground with a ring to create tension between the soil and the water in the tank so that measurements can be performed based on the time elapsed to infiltrate all water contained in the tank, The potential is controlled by a cylinder bubbler connected to the reservoir (Ruiz Sinoga et al 2003).…”
Section: Collection Of Information and Field Workmentioning
confidence: 99%
See 1 more Smart Citation
“…La infiltración fue medida por duplicado en cada una de las 18 parcelas experimentales con un infiltrómetro de disco. Se reguló la presión del infiltrómetro a -2 cm de presión (Aoki y Sereno, 2005). Se tomaron mediciones de infiltración hasta incluir intervalos de tiempo en los que el sistema se situó en un estado estacionario.…”
Section: Compost De Biosólidosunclassified