2019
DOI: 10.1088/1755-1315/302/1/012031
|View full text |Cite
|
Sign up to set email alerts
|

Comparative analysis of temperature loggers used in the development of regimes for heat treatment of food production in autoclaves

Abstract: Heat treatment processes carried out in an autoclave at a temperature from 60 up to 130 °C are usually applied in the canned food production. Actual process lethality value is used as a criterion determining the product readiness and its microbiological safety. It is computed by summing the lethal effect values of heating obtained at different temperatures recorded inside the tin can with product. Loggers (thermographs) are special technical means of temperature measurement and recording in an electronic stora… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…The proposed method was tested in experimental studies on the sterilization regime development of canned food "Murmansk cod liver" for the industrial autoclave ASCAMAT-230. Ellab TrackSense PRO and iButton Data Loggers (sets of loggers that measure and record the temperature in the least heated product area in the tin can, as well as in the autoclave sterilization chamber) were used to determine the actual lethal effect (F-effect) [6]. The software ProcessF was developed for calculating the actual lethal process effect from the product temperature dynamics data.…”
Section: Lean Method Results and Discussionmentioning
confidence: 99%
“…The proposed method was tested in experimental studies on the sterilization regime development of canned food "Murmansk cod liver" for the industrial autoclave ASCAMAT-230. Ellab TrackSense PRO and iButton Data Loggers (sets of loggers that measure and record the temperature in the least heated product area in the tin can, as well as in the autoclave sterilization chamber) were used to determine the actual lethal effect (F-effect) [6]. The software ProcessF was developed for calculating the actual lethal process effect from the product temperature dynamics data.…”
Section: Lean Method Results and Discussionmentioning
confidence: 99%
“…The developed program «Heat treatment process lethality calculation» was used to calculate the actual lethality (Fa, conv. min) of each pasteurization regime (Table 1), taking into account the value of heat resistance characteristic z = 15, obtained as a result of preliminary microbiological studies (base temperature T0 = 80 °C) and experimentally obtained data on the product temperature change during the process using temperature loggers of the TrackSense Pro system (Ellab, Denmark) [12]. The normative pasteurizing effect for this type of canned food was preliminarily determined by microbiological studies and equal to Fn = 52.921 conv.…”
Section: Application and Resultsmentioning
confidence: 99%
“…The actual lethal effect is traditionally determined experimentally by measuring the product temperature in the can center during heat treatment process [12], followed by calculating the actual lethality value using, given in the reference literature, the lethality rates calculated with the following parameters [11]:…”
Section: Rationalementioning
confidence: 99%
“…Energy-efficient and step modes of canned fish products sterilization in steam and water environment have been developed. The mathematical description of the autoclave has been constructed and the warming of different types of fish products in popular sizes of canning containers has been investigated [15]. Reducing time and energy costs of the process and preserving maximum amount of nutrients in the product are of great importance.…”
Section: Brdem-2019mentioning