1980
DOI: 10.21236/ada101070
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Anthropometry of the Hand

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
11
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 2 publications
1
11
0
Order By: Relevance
“…Similarly to studies with human subjects the diameters were chosen to be 3, 6, 9, 12 and 15 mm, all embedded at a depth of 5 mm. Larger nodule is not considered, as the diameter of the indenter (8 mm) is approximately half size compared to the average width of the index finger’s fingertip that is 17 mm, according to reports in [ 35 , 36 ]. Therefore, the robotic identification is performed both for nodules that can be difficult for humans to sense and that are easier to perceive.…”
Section: Robotic Implementation Of the Algorithm For Local Palpationmentioning
confidence: 99%
“…Similarly to studies with human subjects the diameters were chosen to be 3, 6, 9, 12 and 15 mm, all embedded at a depth of 5 mm. Larger nodule is not considered, as the diameter of the indenter (8 mm) is approximately half size compared to the average width of the index finger’s fingertip that is 17 mm, according to reports in [ 35 , 36 ]. Therefore, the robotic identification is performed both for nodules that can be difficult for humans to sense and that are easier to perceive.…”
Section: Robotic Implementation Of the Algorithm For Local Palpationmentioning
confidence: 99%
“…To determine whether there was any evidence of the “fat finger” issue, a series of correlations were conducted between WPM, WER, hand width, index finger width, and index finger length for all conditions. The range of participants’ hand widths was representative of the 1st–75th percentile of adult men and women (White, 1980). No significant correlations were found, p > .05 ( r values ranged from –.35 to +.36).…”
Section: Resultsmentioning
confidence: 99%
“…In case of update failure, the application asks the user for new values of the parameters. To avoid model faults, anthropometrical data, such as in White (1980) can be used for setting ranges for hand measures/ parameters. As the online application can be accessed through common web browsers, installing other specific software is not required to get the STL and pdf files.…”
Section: Customized Splints Online Applicationmentioning
confidence: 99%