2015
DOI: 10.1016/j.joen.2014.10.011
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Evaluation of Accuracy of 2 Electronic Apex Locators with Conventional Radiography: An Ex vivo Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
27
0
9

Year Published

2015
2015
2023
2023

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 34 publications
(36 citation statements)
references
References 28 publications
0
27
0
9
Order By: Relevance
“…In recent years, many different models of EALs have been developed, measuring the impedance with different frequencies between the file tip and fluid within the canal , including the MiniApex Locator (SybronEndo, Sybron Dental, Anaheim, CA, USA) and the Root Zx II (J. Morita MFG Corp., Kyoto, Japan). Current EALs are reliable, exhibit high accuracy and reproducibility in locating the major apical foramen . Additionally, the use of EALs reduces patient exposure to ionising radiation by reducing the number of radiographs to determine the WL.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, many different models of EALs have been developed, measuring the impedance with different frequencies between the file tip and fluid within the canal , including the MiniApex Locator (SybronEndo, Sybron Dental, Anaheim, CA, USA) and the Root Zx II (J. Morita MFG Corp., Kyoto, Japan). Current EALs are reliable, exhibit high accuracy and reproducibility in locating the major apical foramen . Additionally, the use of EALs reduces patient exposure to ionising radiation by reducing the number of radiographs to determine the WL.…”
Section: Introductionmentioning
confidence: 99%
“…Other study showed that RootOR was affected by 2.5% sodium hypochlorite (NaOCl), 0.9% saline solution (NaCl), and 17% EDTA. The authors concluded that better results could be found in dry canals [24]. Endo EZE was the only apex locator that did not show differences with the 4 irrigant solutions.…”
Section: Resultsmentioning
confidence: 93%
“…Quando comparados com o método radiográfico, os estudos tem demonstrado que os LAEs apresentam a mesma precisão em determinar o CT 45 . Sendo que com relação ao método radiográfico, alguns estudos tem encontrado diferenças significativas ao comparar o método radigráfico digital e convencional 46 , e outros estudos apontam para a inexistência de diferenças significativas entre os dois métodos readiográficos combinados à odontometria eletrônica 47 .…”
Section: Discussionunclassified