Comparative Evaluation of Bruker Biotyper and ASTA MicroIDSys for Species Identification in a Clinical Microbiology Laboratory

Abstract: Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI–TOF MS) has been widely used for microbial identification, because of its speed and accuracy, since its introduction to clinical microbiology laboratories. In this study, we evaluated the performance of ASTA MicroIDSys, a newly developed MALDI–TOF, and compared it with the widely used Bruker Biotyper. Microbial identification with the Bruker Biotyper system was performed by using a direct smear method and the Bruker Biotyper da… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 19 publications
0
6
0
Order By: Relevance
“…The computer software associated with the machine MALDI Biotyper (Bruker Daltonics GmbH, Bremen, Germany) uses this “score”; a score value of 2.0 is considered a reliable criterion of bacterial species identification, although the spectra obtained from a single strain are not identical in repeated runs because of a method-inherent noise. Score values between 1.7 and 2.0 are considered reliable for genus identification [ 22 , 23 , 24 , 25 , 27 , 28 , 29 , 30 , 31 , 32 ]. The machine MALDI VITEK MS (bio-Mérieux, Mercy L’Étoile, France) produces a confidence value, which can be reported as a percentage up to 99.9%.…”
Section: Maldi-tof Ms: Principles Of the Proceduresmentioning
confidence: 99%
See 3 more Smart Citations
“…The computer software associated with the machine MALDI Biotyper (Bruker Daltonics GmbH, Bremen, Germany) uses this “score”; a score value of 2.0 is considered a reliable criterion of bacterial species identification, although the spectra obtained from a single strain are not identical in repeated runs because of a method-inherent noise. Score values between 1.7 and 2.0 are considered reliable for genus identification [ 22 , 23 , 24 , 25 , 27 , 28 , 29 , 30 , 31 , 32 ]. The machine MALDI VITEK MS (bio-Mérieux, Mercy L’Étoile, France) produces a confidence value, which can be reported as a percentage up to 99.9%.…”
Section: Maldi-tof Ms: Principles Of the Proceduresmentioning
confidence: 99%
“…Globally, the Microflex Biotyper (Bruker Daltonics GmbH, Bremen, Germany) and VITEK MS (bioMérieux, Marcy l’Etoile, France) are the commercially available MALDI–TOF MS systems currently implemented in clinical microbiology laboratories [ 28 , 29 , 30 , 31 , 32 ]. Recently, a new MALDI–TOF MS system, ASTA MicroIDSys (ASTA Inc., Suwon, Korea), was developed for the identification of clinically important microorganisms, producing discrepant results in the identification of microorganisms not frequently isolated in clinical laboratories, such as Paenibacillus spp.…”
Section: Maldi-tof Ms: Principles Of the Proceduresmentioning
confidence: 99%
See 2 more Smart Citations
“…MALDI-TOF MS is mostly used for the identification of clinically relevant pathogens. It has been reported that this system can effectively identify bacteria even at species level from clinical samples (van Veen et al, 2010;Ponderand et al, 2020;Chung et al, 2021). However, it is increasingly utilised to detect foodborne pathogens in the complex food chain as well (Böhme et al, 2011;de Koster and Brul, 2016;Horváth et al, 2020).…”
Section: Introductionmentioning
confidence: 99%