2021
DOI: 10.4103/ccd.ccd_83_20
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Evaluation of Instrumentation Time, Obturation Time, and Radiographic Quality of Obturation Using Two Rotary Systems and Manual Technique for Primary Molar Pulpectomies – In vivo Study

Abstract: Background: Ideal pulpectomy for primary dentition demands fast, simple procedures, with short treatment times and minimal appointments. Recently, exclusive pediatric rotary files are available for use in primary teeth. There is a paucity of literature on the clinical efficacy of pediatric rotary files. Hence, this study was planned to evaluate and compare pediatric rotary files and K-files. Aim: The aim of this study was to evaluate and compare instrumentation time, ob… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

3
10
0
3

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(16 citation statements)
references
References 36 publications
3
10
0
3
Order By: Relevance
“…Usage of hand files in preparation of curved canals frequently causes undesirable aberrations such as elbows, zips and danger zones because of their inherent stiffness [ 35 ]. Consequently, usage of stainless‑steel files in narrow curved canals is considered to be difficult as apical enlargement is limited, hindering good quality obturation [ 36 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Usage of hand files in preparation of curved canals frequently causes undesirable aberrations such as elbows, zips and danger zones because of their inherent stiffness [ 35 ]. Consequently, usage of stainless‑steel files in narrow curved canals is considered to be difficult as apical enlargement is limited, hindering good quality obturation [ 36 ].…”
Section: Discussionmentioning
confidence: 99%
“…Hence, a greater amount of dentin was removed by hand files than by rotary Kedo S Square file,which could be attributed to the non-cutting safety tip of the Kedo S Square files and to the indiscriminate and aggressive cutting action of stainless-steel files [ 36 ]. H type instrument has better cutting efficiency than K type instruments because H file has a positive rake angle where its blade cuts rather than scarps dentin unlike the K file having a negative rake angle [ 53 ].…”
Section: Discussionmentioning
confidence: 99%
“…Todos os estudos avaliados neste trabalho demonstraram que o uso das limas rotatórias diminui consideravelmente o tempo de instrumentação dos canais de dentes decíduos, quando comparados ao tempo de instrumentação das limas manuais. Além disso, Shah et al, (2021) A presença dos pais durante o tratamento dentário não influencia no comportamento das crianças. Os pais e os dentistas observaram uma piora no comportamento das crianças quando os pais estavam ausentes.…”
Section: Discussionunclassified
“…Os estudos que abordaram a qualidade da obturação em canais de dentes decíduos mostraram que o preenchimento desses canais obteve melhor qualidade quando foram tratados através de instrumentos endodônticos rotatórios, quando comparados aos instrumentos manuais. (Boonchoo et al, 2020;Govindaraju et al, 2017;Jeevanandan et al, 2021;Lakshmanan et al, 2020;Pawar et al, 2021;Shah et al, 2021).…”
Section: Discussionunclassified
See 1 more Smart Citation