2020
DOI: 10.3390/en13051227
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Evaluation of Lifetime of Three-Level Inverters in Grid-Connected Photovoltaic Systems

Abstract: The cost of the PV energy reduction is still required to increase the penetration level of PV systems in the energy market. The reliability of PV inverters is one of the important aspects to be enhanced in order to reduce the cost of PV energy, since it is closely related to the maintenance cost and the annual energy production. In this paper, the lifetime of NPC and T-type inverters, which are three-level inverter topologies that are widely used for PV systems, are comparatively evaluated with a 30 kW grid-co… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…It can be seen from Fig. 13 It indicates that 1 % of the population is expected to fail after 20.5 years and 10 % of the population is forecasted to be failed after 40.5 years.…”
Section: System-level Lifetime Assessment Based On Monte Carlo Analysis Methodsmentioning
confidence: 92%
See 1 more Smart Citation
“…It can be seen from Fig. 13 It indicates that 1 % of the population is expected to fail after 20.5 years and 10 % of the population is forecasted to be failed after 40.5 years.…”
Section: System-level Lifetime Assessment Based On Monte Carlo Analysis Methodsmentioning
confidence: 92%
“…Accordingly, there are various attempts to improve the efficiency of PV inverters in different aspects such as inverter topologies, power device technology and pulse width modulation methods [6]- [11]. Furthermore, the reliability of PV inverters has been analyzed by considering the impact of various factors such as mission profile [12]- [16], inverter topology [12], [13], DC-to-AC ratio [14], [15], and panel degradation rate [16]. However, there is a still lack of study on more comprehensive analysis on both efficiency and reliability together including the impacts of various factors.…”
Section: Introductionmentioning
confidence: 99%
“…In addition to cooling, the lifetime of converters can also be enhanced by using different converter topologies [15,23] in three-level converters. This paper, however, focuses on a two-level back-to-back converter.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Therefore, the lifetime of the power device is not the limiting factor to increase the R DC/AC in Aalborg and Iza. However, it is worthwhile mentioning that the R DC/AC is typically chosen between 1.0 and 1.6 since there is no benefit of the oversizing PV array on the Levelized Cost of Energy (LCOE) [14].…”
Section: B Lifetime Evaluationmentioning
confidence: 99%
“…The mission profile based lifetime estimation of NPC inverter has been performed in the previous work in [14]. This study is extended from that approach to investigate the effect of the installation locations on the lifetime of the NPC inverter and DC/AC ratio selection.…”
Section: Introductionmentioning
confidence: 99%