Comparative evaluation of liver, spleen, and kidney stiffness in HIV-monoinfected pediatric patients via shear wave elastography

Abstract: Background/aim: This study aimed to evaluate the stiffness of the liver, spleen, and kidneys in HIV-monoinfected children via shear wave elastography (SWE). Materials and methods: Twenty-one HIV-monoinfected children and 37 healthy subjects were included in this study. Livers, spleens, and kidneys of the participants were examined via ultrasound and SWE. Patients were divided into two groups according to the presence of pathologic ultrasonographic findings. Routine laboratory tests were also recorded. Stiffnes… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 22 publications
0
2
0
Order By: Relevance
“…Some studies concerning splenic stiffness in children with chronic liver disease provide normal values in small control groups, but these were obtained from US machines from various manufacturers, thus compromising any reliable comparison of the values [ 6 , 18 ]. Splenic stiffness measurements from these manufacturers were either expressed in kilopascal (kPa), e.g., with a median of 17.85±1.3 kPa on 10 children ages 4 to 14 years [ 5 ], or expressed both in kPa and m/s, e.g., with a median of 16.8 kPa (1.6–22.8 kPa) and 2.4 m/s (2.0–2.7 m/s) in 37 patients (0.5–18.5 years) [ 19 ].…”
Section: Discussionmentioning
confidence: 99%
“…Some studies concerning splenic stiffness in children with chronic liver disease provide normal values in small control groups, but these were obtained from US machines from various manufacturers, thus compromising any reliable comparison of the values [ 6 , 18 ]. Splenic stiffness measurements from these manufacturers were either expressed in kilopascal (kPa), e.g., with a median of 17.85±1.3 kPa on 10 children ages 4 to 14 years [ 5 ], or expressed both in kPa and m/s, e.g., with a median of 16.8 kPa (1.6–22.8 kPa) and 2.4 m/s (2.0–2.7 m/s) in 37 patients (0.5–18.5 years) [ 19 ].…”
Section: Discussionmentioning
confidence: 99%
“…In adults, the convex transducer is used for performing the elastography studies. There is only one study on SS assessed in a pediatric population and the convex transducer was used [35]. Despite the lack of data, the transducer, either the linear or the curvilinear one, might be chosen depending on the body habitus and age of the patient, as we do for the assessment of the LS in children.…”
Section: Arfi-based Techniques: Transducer (Frequency) Selectionmentioning
confidence: 99%