2016
DOI: 10.4103/0976-237x.177108
|View full text |Cite
|
Sign up to set email alerts
|

Comparative evaluation of pressure generated on a simulated maxillary oral analog by impression materials in custom trays of different spacer designs: An in vitro study

Abstract: Introduction:Literature reveals that masticatory load on denture bearing tissues through complete dentures should be maximum on primary stress bearing areas and least on relief area in accordance with the histology of underlying tissues. A study to validate the existing beliefs was planned to compare the pressure on mucosa using selective pressure technique and minimal pressure technique, with the incorporation of two different impression materials utilizing the pressure sensors during secondary impression pro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
11
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 22 publications
1
11
0
Order By: Relevance
“…However, when the palate was evaluated the physical impressions compressed the tissues and demonstrated a negative deviation of 120 μm while the digital impressions all demonstrated a positive deviation ranging from 106 to 236 μm. This is consistent with previous studies that show that physical impressions generate significant compressive forces which can depress the soft tissues . The lack of pressure from a digital impression may cause prosthetics to fit more loosely compared to those fabricated with physical impressions.…”
Section: Discussionsupporting
confidence: 92%
See 3 more Smart Citations
“…However, when the palate was evaluated the physical impressions compressed the tissues and demonstrated a negative deviation of 120 μm while the digital impressions all demonstrated a positive deviation ranging from 106 to 236 μm. This is consistent with previous studies that show that physical impressions generate significant compressive forces which can depress the soft tissues . The lack of pressure from a digital impression may cause prosthetics to fit more loosely compared to those fabricated with physical impressions.…”
Section: Discussionsupporting
confidence: 92%
“…This is consistent with previous studies that show that physical impressions generate significant compressive forces which can depress the soft tissues. 19 The lack of pressure from a digital impression may cause prosthetics to fit more loosely compared to those fabricated with physical impressions. The ability for intraoral digital impression systems to capture and stitch soft tissue data is relatively recent.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…23,24 During the clinical impression procedure, the minimum applied pressure is 1 kg/cm 2 , which is unequal distributedbigger on the alveolar ridge, less on the midline. 25…”
Section: Original Articlementioning