2023
DOI: 10.5005/jp-journals-10024-3399
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Evaluation of Retention and Vertical Marginal Accuracy of Co–Cr Copings Fabricated Using Three Different Techniques: An In Vitro Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…Afterward, 12 articles were excluded because 5 studies analyzed the marginal and internal discrepancy values after completing ceramic veneering procedures, 1 investigation did not provide the quantitatively measured marginal and internal discrepancies, 3 studies did not provide the manufacturer of the metal printer used to fabricate the specimens, and 3 studies did not test metal AM techniques. A total of 31 articles (30 in vitro [35][36][37][38][39][40][41][42][43][44][45][46][47][48][49][50][51][52][53][55][56][57][58][59][60][61][62][63][64][65] and 1 clinical 54 ) were included in the present systematic review.…”
Section: Study Selectionmentioning
confidence: 99%
See 4 more Smart Citations
“…Afterward, 12 articles were excluded because 5 studies analyzed the marginal and internal discrepancy values after completing ceramic veneering procedures, 1 investigation did not provide the quantitatively measured marginal and internal discrepancies, 3 studies did not provide the manufacturer of the metal printer used to fabricate the specimens, and 3 studies did not test metal AM techniques. A total of 31 articles (30 in vitro [35][36][37][38][39][40][41][42][43][44][45][46][47][48][49][50][51][52][53][55][56][57][58][59][60][61][62][63][64][65] and 1 clinical 54 ) were included in the present systematic review.…”
Section: Study Selectionmentioning
confidence: 99%
“…The selected articles were classified based on the evaluation method used to assess the fit of the Co-Cr frameworks, namely manufacturing accuracy, 35,36 the dual-scan 37,38 and triple-scan method, 39 stereomicroscope, [40][41][42][43][44][45] optical coordinate measurement machine (CMM), 46 microCT, 47,48 profilometer, 49 and silicone replica technique. [50][51][52][53][54][55][56][57][58][59][60][61][62][63][64][65] Additionally, each group was subdivided into six subgroups based on the manufacturer used to fabricate the SLM Co-Cr frameworks, namely 3D Systems, 35,62 Bego, 51,54 Concept Laser, [37][38][39]41,42,47,48,52,56,58 EOS, 36,40,…”
Section: Study Characteristicsmentioning
confidence: 99%
See 3 more Smart Citations