2021
DOI: 10.1002/bdd.2299
|View full text |Cite
|
Sign up to set email alerts
|

Comparative in silico prediction of P‐glycoprotein‐mediated transport for 2010–2020 US FDA‐approved drugs using six Web‐tools

Abstract: P‐glycoprotein (P‐gp) is an efflux pump implicated in pharmacokinetics and drug–drug interactions. The identification of its substrates is consequently an important issue, notably for drugs under development. For such a purpose, various in silico methods have been developed, but their relevance remains to be fully established. The present study was designed to get insight about this point, through determining the performance values of six freely accessible Web‐tools (ADMETlab, AdmetSAR2.0, PgpRules, pkCSM, Swi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 35 publications
0
10
0
Order By: Relevance
“…All the tested compounds decreased the pBAD at Ser-99 without change in total BAD expression (Figure 6). Since the active compounds (4e, 4f, 4i, and NPB as a comparison) displayed efficacy against MCF-7 cells, the in silico ADMET properties (8 parameters) of these compounds were determined by using vNN-ADMET online platform [29]. The results are tabulated in Table 4.…”
Section: Resultsmentioning
confidence: 99%
“…All the tested compounds decreased the pBAD at Ser-99 without change in total BAD expression (Figure 6). Since the active compounds (4e, 4f, 4i, and NPB as a comparison) displayed efficacy against MCF-7 cells, the in silico ADMET properties (8 parameters) of these compounds were determined by using vNN-ADMET online platform [29]. The results are tabulated in Table 4.…”
Section: Resultsmentioning
confidence: 99%
“…For each individual or combination of web tool(s), the area under the receiver operating characteristics curve (ROC AUC) was determined to be the first prediction performance parameter using GraphPad Prism software (version 5.0; GraphPad Software Inc.) as previously described. [ 26 ] The Matthews correlation coefficient (MCC) was then calculated as a second prediction performance parameter. The MCC measures the correlation between predictions and real values.…”
Section: Methodsmentioning
confidence: 99%
“…The MCC measures the correlation between predictions and real values. [ 26 ] Thereafter, the prediction of P‐gp activity inhibition by 762 pesticides belonging to various chemical classes was evaluated using the most efficient individual web tool or combination of tools.…”
Section: Methodsmentioning
confidence: 99%
“…The in silico models rely on the sequence similarities rather than functional similarities in predicting 3D conformation, which impede their interests as alternatives to the in vitro assays 123 . For instance, a recent study demonstrated that all six freely accessible Web-tools (ADMETlab, AdmetSAR2.0, PgpRules, pkCSM, SwissADME and vNN-ADMET) are poorly to meet the criteria for predicting P-gp-mediated transport 124 .…”
Section: Current Approach In Transporter Studymentioning
confidence: 99%
“…For instance, a recent study demonstrated that all six freely accessible Web-tools (ADMETlab, AdmetSAR2.0, PgpRules, pkCSM, SwissADME and vNN-ADMET) are poorly to meet the criteria for predicting P-gp-mediated transport [124].…”
Section: In Silico Modelsmentioning