2006
DOI: 10.1128/aac.01622-05
|View full text |Cite|
|
Sign up to set email alerts
|

Comparative In Vitro Efficacies and Antimicrobial Durabilities of Novel Antimicrobial Central Venous Catheters

Abstract: We investigated the efficacies and durability of novel antimicrobial central venous catheters (CVCs) in preventing the adherence of microbial organisms to the surfaces of the CVCs. Novel antimicrobial CVCs investigated in this in vitro study were impregnated with antibiotics (minocycline and rifampin), with Oligon agent (silver, platinum, and carbon black), with approved antiseptics (chlorhexidine and silver sulfadiazine), or with a novel antiseptic agent, gendine, which contains gentian violet and chlorhexidi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
31
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 62 publications
(31 citation statements)
references
References 50 publications
0
31
0
Order By: Relevance
“…However, some existing antimicrobial-treated catheters designed to prevent catheter colonization may have partial clinical efficacy, particularly against drug-resistant pathogens, and limited durability of antimicrobial activity (8,(10)(11)(12)(13) partly due to their inability to control biofilm formation and combat biofilm-nested microorganisms, which can have MICs of up to 1,000 times higher than their MICs against their free-floating planktonic counterparts (8,(14)(15)(16).…”
mentioning
confidence: 99%
“…However, some existing antimicrobial-treated catheters designed to prevent catheter colonization may have partial clinical efficacy, particularly against drug-resistant pathogens, and limited durability of antimicrobial activity (8,(10)(11)(12)(13) partly due to their inability to control biofilm formation and combat biofilm-nested microorganisms, which can have MICs of up to 1,000 times higher than their MICs against their free-floating planktonic counterparts (8,(14)(15)(16).…”
mentioning
confidence: 99%
“…Moreover, the use of tap water or sodium chloride solution can substitute the use of antiseptics like chlorhexidine and gentian violet in reducing the adherence of Candida albicans to the catheters [10,13]. Also, the effectiveness of sodium chloride solution (0.9%) in this study highlights the significant use of this solution instead of antimicrobial coated central venous catheter, as well as its effect is comparable to the irrigation with antimicrobials [14]. The effect of certain concentrations of sodium chloride solutions may be related to the interaction of chloride solution with the materials of catheter.…”
Section: Discussionmentioning
confidence: 69%
“…These gendine-coated devices showed antimicrobial efficacy and durability against a wide range of bacteria and fungi (14,(17)(18)(19). Further, gendine-coated urinary catheters prevented urinary tract infection with E. coli in a rabbit model (15).…”
Section: Resultsmentioning
confidence: 99%
“…Our team previously developed gendine-coated medical devices, such as central venous catheters (CVC), urinary catheters, endotracheal tubes, and gloves made of different types of polymers (14,(17)(18)(19). These gendine-coated devices showed antimicrobial efficacy and durability against a wide range of bacteria and fungi (14,(17)(18)(19).…”
Section: Resultsmentioning
confidence: 99%