Comparative Laboratory Evaluation of Premolded Joints for Medium Voltage Cables

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
4
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 4 publications
2
4
0
Order By: Relevance
“…Present results show that joint types A and D exhibit an increase in breakdown voltage due to aging. It is worth mentioning here that in a similar previous study, pre-molded MV joints displayed an increase in U b values due to cycling aging [21]. The results of U b values suggest that after aging, joint type A has better performance compared to others.…”
Section: Pd Measurementssupporting
confidence: 69%
See 2 more Smart Citations
“…Present results show that joint types A and D exhibit an increase in breakdown voltage due to aging. It is worth mentioning here that in a similar previous study, pre-molded MV joints displayed an increase in U b values due to cycling aging [21]. The results of U b values suggest that after aging, joint type A has better performance compared to others.…”
Section: Pd Measurementssupporting
confidence: 69%
“…The results show that there are large differences in the breakdown values of un-aged joints of different manufacturers. It is well known that even the joints of the same manufacturer and same production batch display a large statistical spread in their breakdown values [21]. Present results show that joint types A and D exhibit an increase in breakdown voltage due to aging.…”
Section: Pd Measurementssupporting
confidence: 46%
See 1 more Smart Citation
“…In the incubation period, it could be assumed that the expansion coefficient of the EPR polymer decreased faster than that of SCT polymer. As a result, the deformation of EPR became more severe [23,24].…”
Section: Characteristics Of Epr Insulation and Sct Sample Under Low Tmentioning
confidence: 99%
“…As the core equipment for high-voltage power grid energy transmission, XLPE (Cross-linked Poly-ethylene) cables have a significant impact on the reliability of power grid operation [1]- [3]. Compared with the cable body, cable joints are prone to insulation degradation and breakdown due to their complex structure and on-site production.…”
Section: Introductionmentioning