2009
DOI: 10.1016/j.aca.2009.05.031
|View full text |Cite
|
Sign up to set email alerts
|

Comparative studies of neodymium (III)-selective PVC membrane sensors

Abstract: a b s t r a c tSensors based on two neutral ionophores, N,N -bis((1H-pyrrol-2-yl)methylene)cyclohexane-1,2-diamine (L 1 ) and 3,3 -(cyclohexane-1,2-diylbis(azan-1-yl-1-ylidene)bis(methan-1-yl-1-ylidene)bis(5-hydroxymethyl)pyridine-2-ol) (L 2 ) are described for quantification of neodymium (III). Effect of various plasticizers; 2-nitrophenyloctylether (o-NPOE), dibutyl butylphosphonate (DBBP), tri-n-butyl phosphates (TBP), dioctylpthalate (DOP) and chloronapthalen (CN) and anion excluder, sodiumtetraphenylborat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
32
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 186 publications
(33 citation statements)
references
References 36 publications
1
32
0
Order By: Relevance
“…As a result, the content of PVC increases on the surface of the PIMs after extraction. This assumption is consistent with similar phenomenon in other reports [34,38,[40][41][42].…”
Section: Transport Mechanismsupporting
confidence: 93%
“…As a result, the content of PVC increases on the surface of the PIMs after extraction. This assumption is consistent with similar phenomenon in other reports [34,38,[40][41][42].…”
Section: Transport Mechanismsupporting
confidence: 93%
“…The obtained surface coverage is 99.96% that is assumed for an intensive and dense film. The standard rate constant, k 0 , can be calculated from equation R ct = RT/(nF) 2 Ak 0 C, where A is the electrode area, n = 1 (electron transfer number of Fe(CN) 6 3−/4− ), C is the concentration of Fe(CN) 6 3−/4− , F is faraday Fig. 5.…”
Section: Electrochemical Evidence For the So/gce By CVmentioning
confidence: 99%
“…These electrodes are employed for important aims such as metal analysis [1,2], sensor applications [3][4][5][6][7][8][9][10][11][12], drug determination [13][14][15][16] and creating molecular junctions for molecular electronic devices [17,18]. Recently, graphene, a carbon material, and nanoparticles modified electrodes have been prepared and various literatures have been reported for the determination of biological molecules with high sensitivity [19,20].…”
Section: Introductionmentioning
confidence: 99%
“…The composition of a membrane plays a very important role in determining the sensitivity and selectivity of an ionophore [41][42][43][44][45]. In order to investigate the effect of composite materials such as PVC matrix, DBP plasticizer, ionophore and sodium tetrakis (4-flurophenyl)borate additive, 9…”
Section: Membrane Compositionmentioning
confidence: 99%