2005
DOI: 10.1016/j.ijbiomac.2004.12.003
|View full text |Cite
|
Sign up to set email alerts
|

Comparative study of hyaluronic derivatives: rheological behaviour, mechanical and chemical degradation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

3
24
0
4

Year Published

2006
2006
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 36 publications
(31 citation statements)
references
References 31 publications
3
24
0
4
Order By: Relevance
“…Each author certifies that his or her institution approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained. high-weight molecules contribute to form a high-viscosity solution, which serves as a lubricant and shock absorber [2,25], among other functions. Viscosupplementation reportedly relieves pain [13] but it also is considered a disease-modifying OA drug [14,29] with benefits that have been observed in a period of 6 months to 2 years [22].…”
Section: Introductionmentioning
confidence: 99%
“…Each author certifies that his or her institution approved the human protocol for this investigation, that all investigations were conducted in conformity with ethical principles of research, and that informed consent for participation in the study was obtained. high-weight molecules contribute to form a high-viscosity solution, which serves as a lubricant and shock absorber [2,25], among other functions. Viscosupplementation reportedly relieves pain [13] but it also is considered a disease-modifying OA drug [14,29] with benefits that have been observed in a period of 6 months to 2 years [22].…”
Section: Introductionmentioning
confidence: 99%
“…For relatively small HA derivatives or fragments, HPLC [8][9][10][11][12] or HPLC-MS [13,14] have been employed. For large underivatized HA, size-exclusion chromatography (SEC) [15][16][17][18][19][20][21][22], SEC combined with viscometry [23][24][25], SEC combined with light scattering (LS) detection (SEC-LS) [23][24][25][26][27][28][29][30][31][32], SEC combined with MALDI-MS (SEC-MALDI-MS) [33][34][35] have been used.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, the operation of BMM has certain risks since concentrated sulphuric acid is used to treat samples and pretreatment is quite complex (Bitter & Muir, 1962). Although other biochemical methods such as specific hyaluronidase digestion and HPLC methods have certain advantages on accuracy and precision, they are rarely applied to determine large batch fermentation broth samples (Gu & Yan, 2003;Prieto et al, 2005).…”
Section: Introductionmentioning
confidence: 99%