2015
DOI: 10.1016/j.isatra.2015.01.011
|View full text |Cite
|
Sign up to set email alerts
|

Comparative study of reference currents and DC bus voltage control for Three-Phase Four-Wire Four-Leg SAPF to compensate harmonics and reactive power with 3D SVM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
33
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 25 publications
(33 citation statements)
references
References 19 publications
0
33
0
Order By: Relevance
“…Recently, about the world the industrial and domestic equipment are progressively use the single and three phase unbalanced non-linear loads, such as rectifiers, power supplies and speed drivers, include nonlinear dynamics that entail the generation in four wire distribution networks the current harmonics, zero sequence current, and consumption of reactive power, these harmonics, zero sequence current, and reactive power causing harmful effects, such as the distortion of loads and waveform of line voltages, boosted ageing of loads and disturbing the other electronic equipments connected to the four wire distribution networks [1][2][3][4].…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…Recently, about the world the industrial and domestic equipment are progressively use the single and three phase unbalanced non-linear loads, such as rectifiers, power supplies and speed drivers, include nonlinear dynamics that entail the generation in four wire distribution networks the current harmonics, zero sequence current, and consumption of reactive power, these harmonics, zero sequence current, and reactive power causing harmful effects, such as the distortion of loads and waveform of line voltages, boosted ageing of loads and disturbing the other electronic equipments connected to the four wire distribution networks [1][2][3][4].…”
Section: Introductionmentioning
confidence: 99%
“…The modern filtering solutions to eliminate these harmonics and zero sequence current, and to improve the quality of electric power are, the four leg shunt active power filters (SAPFs), they can extensively studied and effectively solution for improve the mainly power factor by the elimination of harmonic currents and zero sequence current, and the compensation of reactive power into the point of common coupling (PCC) in three phase four wire electrical networks [3,[5][6][7]. The most powerful converters used in four leg shunt active power filter have been the two-level four leg inverters.…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations