2024
DOI: 10.3390/ma17061246
|View full text |Cite
|
Sign up to set email alerts
|

Comparative Study of the Influence of Heat Treatment on Fracture Resistance of Different Ceramic Materials Used for CAD/CAM Systems

Andrea Ordoñez Balladares,
Cristian Abad-Coronel,
Joao Carlos Ramos
et al.

Abstract: The aim of this study was to compare the influence of heat treatment on fracture resistance (FR) of different ceramic materials used for CAD/CAM systems. Methods: Eighty monolithic restorations were designed using the same parameters and milled with a CAD/CAM system (CEREC SW 5.0, PrimeMill, Dentsply-Sirona™, Bensheim, Germany), forming five study groups: Group 1 (n = 10), CEREC Tessera (Dentsply-Sirona™, Bensheim, Germany) crystallized (CCT), Group 2 (n = 10), CEREC Tessera uncrystallized (UCT), Group 3 (n = … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 78 publications
0
3
0
Order By: Relevance
“…This discrepancy highlights the importance of material sensitivity to variations in the thermal protocol, suggesting that indiscriminate increases in time and temperature do not necessarily guarantee improvements in desired mechanical properties. This was demonstrated by Ordonez et al who analyzed and compared in a recent study the FS of four CAD/CAM glass ceramics, showing that the AHT of CEREC Tessera at 760 • C for 2 min obtained the best results of 437,462 ± 69.17 MPa [58].…”
Section: Discussionmentioning
confidence: 71%
“…This discrepancy highlights the importance of material sensitivity to variations in the thermal protocol, suggesting that indiscriminate increases in time and temperature do not necessarily guarantee improvements in desired mechanical properties. This was demonstrated by Ordonez et al who analyzed and compared in a recent study the FS of four CAD/CAM glass ceramics, showing that the AHT of CEREC Tessera at 760 • C for 2 min obtained the best results of 437,462 ± 69.17 MPa [58].…”
Section: Discussionmentioning
confidence: 71%
“…These properties are crucial for determining the material's suitability for different dental applications. According to a few data from the literature, some aspects can be summarized below to compose the final idea that materials that share a clinical indication can behave very differently (Table 7) in the same condition [40][41][42][43].…”
Section: Discussionmentioning
confidence: 99%
“…Lithium disilicate -LD PS e.max CAD, Ivoclar 14.1 [41] 402.9 ± 78.4 [4] 434.96 ± 88.01 [40] 14.1 [41] 6.63 ± 0.21 [42] 103 [43] Advanced Lithium Disilicate -ALD Tessera Blocks, Sirona 21.4 [41] 282.1 ± 64.4 [4] 437.46 ± 69.17 [40] 21.4 [41] 7.37 ± 0.19 [42] 103 [43] Author Contributions:…”
mentioning
confidence: 99%