2022
DOI: 10.1021/jasms.2c00004
|View full text |Cite
|
Sign up to set email alerts
|

Comparing Selected-Ion Collision Induced Unfolding with All Ion Unfolding Methods for Comprehensive Protein Conformational Characterization

Abstract: Structural analysis by native ion mobility−mass spectrometry provides a direct means to characterize protein interactions, stability, and other biophysical properties of disease-associated biomolecules. Such information is often extracted from collision-induced unfolding (CIU) experiments, performed by ramping a voltage used to accelerate ions entering a trap cell prior to an ion mobility separator. Traditionally, to simplify data analysis and achieve confident ion identification, precursor ion selection with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
24
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(26 citation statements)
references
References 52 publications
2
24
0
Order By: Relevance
“…A Synapt G2-S traveling wave ion mobility spectrometry quadrupole time-of-flight (TWIMS-q-ToF) IM-MS system (Waters, Milford, MA) was used for native IM-MS and all multiplexed collision-induced unfolding (MPX-CIU) experiments. , MassLynx software V4.1 (Waters) was utilized for instrument control and data acquisition. Instrumental parameters for native IM-MS experiments were optimized (Table S1) to minimize collisional and electrostatic ion heating , and kept consistent for all multiplicate MS and CIU experiments.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A Synapt G2-S traveling wave ion mobility spectrometry quadrupole time-of-flight (TWIMS-q-ToF) IM-MS system (Waters, Milford, MA) was used for native IM-MS and all multiplexed collision-induced unfolding (MPX-CIU) experiments. , MassLynx software V4.1 (Waters) was utilized for instrument control and data acquisition. Instrumental parameters for native IM-MS experiments were optimized (Table S1) to minimize collisional and electrostatic ion heating , and kept consistent for all multiplicate MS and CIU experiments.…”
Section: Methodsmentioning
confidence: 99%
“…Protein ion unfolding experiments were performed without quadrupole isolation per charge state by applying an “all-ion/charge multiplexed” approach, , allowing simultaneous acquisition of unfolding pathways for all charge states observed; the broad-band CIU approach reduced the time required to probe all unfolding pathways of interest from surface-sampled proteins. Reproducibility of CIU curves can be affected by chemical noise and low signal-to-noise ratio (S/N); hence, to generate average or representative CIU curves, all IM-MS analyses were performed in triplicate.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The CIU curve is similar to ones measured by ion mobility, in which the increase in CCS during CIU frequently ranges from 30-50%. [56][57][58][59][60] Figure 5. Orbitrap CCS of native-like carbonic anhydrase (9+, 29 kDa monomer, m/z 3233) relative to the collision energy used for in-source CID to cause collisional heating.…”
Section: Applications Of Orbitrap Ccs Measurements For Native Proteinsmentioning
confidence: 99%
“…The CIU curve is similar to ones measured by ion mobility, in which the increase in CCS during CIU frequently ranges from 30-50%. [58][59][60][61][62] Figure 5. Orbitrap CCS of native-like carbonic anhydrase (9+, 29 kDa monomer, m/z 3233) relative to the collision energy used for in-source collisional activation to cause collisional heating.…”
Section: Applications Of Orbitrap Ccs Measurements For Native Proteinsmentioning
confidence: 99%