2018
DOI: 10.1016/j.joen.2018.07.021
|View full text |Cite
|
Sign up to set email alerts
|

Comparison between Single-file Rotary Systems: Part 2—The Effect of Length of the Instrument Subjected to Cyclic Loading on Cyclic Fatigue Resistance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
14
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(15 citation statements)
references
References 24 publications
1
14
0
Order By: Relevance
“…Previous studies showed that XPS has excellent resistance to cyclic fatigue compared to WOG [19][20][21][22]. However, the torque at failure was found to be very low (0.84 ± 0.11 N·cm) [21] which is due to the file design.…”
Section: Discussionmentioning
confidence: 91%
See 1 more Smart Citation
“…Previous studies showed that XPS has excellent resistance to cyclic fatigue compared to WOG [19][20][21][22]. However, the torque at failure was found to be very low (0.84 ± 0.11 N·cm) [21] which is due to the file design.…”
Section: Discussionmentioning
confidence: 91%
“…XPS achieves a final apical preparation of at least 30/0.04 [17][18][19]. XPS was found to have superior cyclic fatigue performance compared to other file systems [19][20][21][22]. WaveOne Gold (WOG; Dentsply Sirona, York, PA) system is an updated version of the WaveOne (WO; Dentsply Sirona) single-file system.…”
Section: Introductionmentioning
confidence: 99%
“…To optimally analyze the properties of a heat treatment, it should be used the same designed instruments at the same conditions due to remove bias caused by different volumes of the alloy, cross-sectional shape and cutting performance (21,23). Cross-sectional design and type of mechanical movement are considered crucial factors in the affection of cyclic fatigue resistance of an endodontic instrument (24,25).…”
Section: Discussionmentioning
confidence: 99%
“…In the last decades, considerable progress in endodontic instruments, equipment and materials has resulted in simpler, safer and more efficient root canal procedures. For instance, single-file nickel-titanium systems prevent cross-infections and optimize root canal treatment (Azim, et al, 2018a;Azim, et al, 2018b). Single-file systems have gained wide interest and a growing body of evidence regarding physical and microbiological features supports the choice of these instruments for endodontic therapy.…”
Section: Introductionmentioning
confidence: 99%
“…Single-file systems have gained wide interest and a growing body of evidence regarding physical and microbiological features supports the choice of these instruments for endodontic therapy. Most current single-file systems are available in different tapers and usually exhibit innovative manufacturing processes that provide great flexibility such as XP-Endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Switzerland), Reciproc Blue (VDW GmbH, Munich, Germany), and ProDesign Logic (Easy Equipamentos Odontológicos, Belo Horizonte, MG, Brazil) (Azim, et al, 2018b).…”
Section: Introductionmentioning
confidence: 99%