Comparison of 7 Different Sensors for Detecting Low Respiratory Rates Using a Single Breath Detection Algorithm in Nonintubated, Sedated Volunteers

Abstract: BACKGROUND: Numerous technologies are used to monitor respiratory rates in nonintubated patients. No technology has emerged as the standard. The primary aim of this study was to assess the limits of agreement between a reference sensor signal (respiratory inductance plethysmography bands) and 7 alternative sensor signals (nasal capnometer, nasal pressure transducer, oronasal thermistor, abdominal accelerometer, transpulmonary electrical impedance, peritracheal microphone, and photoplethysmography) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
20
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(20 citation statements)
references
References 21 publications
0
20
0
Order By: Relevance
“…Some methodological limitations of the study require caution in the interpretation of their findings, but useful information for further research have been provided [65]. The authors found that an abdominal accelerometer and a capnometer showed better performances compared to a nasal pressure transducer, an oronasal thermistor, a peritracheal microphone, transthoracic impedance sensors, and photoplethysmography [65]. The last two techniques listed showed the worst performances [65].…”
Section: Measurement and Computingmentioning
confidence: 98%
See 4 more Smart Citations
“…Some methodological limitations of the study require caution in the interpretation of their findings, but useful information for further research have been provided [65]. The authors found that an abdominal accelerometer and a capnometer showed better performances compared to a nasal pressure transducer, an oronasal thermistor, a peritracheal microphone, transthoracic impedance sensors, and photoplethysmography [65]. The last two techniques listed showed the worst performances [65].…”
Section: Measurement and Computingmentioning
confidence: 98%
“…However, impedance plethysmography usually underperforms compared to techniques measuring respiration-related chest wall movements with strain sensors. This has been shown in different conditions, including exercise, ambulatory monitoring, and drug-induced respiratory depression [24,64,65]. Strain sensors (e.g., resistive, capacitive, and inductive sensors) may be suitable solutions to register the respiration-induced movements of the thorax or the abdomen and measure f R continuously [24].…”