2018
DOI: 10.1016/j.diagmicrobio.2017.10.020
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Abbott Architect ® , Siemens Immulite ® , and Diasorin Liaison ® for determination of Epstein–Barr virus serological diagnosis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
6
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 18 publications
1
6
0
Order By: Relevance
“…According to our results, this algorithm can be used for Euroimmun®, Vidas®, and Architect® tests. However, because the specificity of the EBNA IgG results obtained by Immulite® was 68.1% although their sensitivity was 100%, the application of the algorithm on this test was detected to be difficult similar to the finding of a study conducted in France 11 …”
Section: Discussionsupporting
confidence: 56%
“…According to our results, this algorithm can be used for Euroimmun®, Vidas®, and Architect® tests. However, because the specificity of the EBNA IgG results obtained by Immulite® was 68.1% although their sensitivity was 100%, the application of the algorithm on this test was detected to be difficult similar to the finding of a study conducted in France 11 …”
Section: Discussionsupporting
confidence: 56%
“… 13 21 25 Second, while we are not aware of published studies that directly compared the recomLine EBV IgG immunoblot with the liaison CLIA applied in our work, in a previous comparative study, the sensitivity of the recomLine EBV IgG immunoblot was not higher than that of another CLIA method (Architect; Abbott, Wiesbaden, Germany), 25 which is similar to the CLIA Method used in our work. 26 Third, when we re-tested 28 sera, which were EBNA-1 IgG and VCA IgG negative, as determined in undiluted sera by the Liaison CLIA, by EBV immunoblots, all of these sera were likewise EBV seronegative in the EBV immunoblot (unpublished observation). Altogether, the available evidence therefore clearly argues against a higher sensitivity of the EBV IgG immunoblot as compared with determination of EBNA-1 IgG and VCA IgG in undiluted sera by the liaison CLIA.…”
Section: Discussionmentioning
confidence: 96%
“…Previous studies on VCA-IgA detection generally used ELISA and IFA, [4] CLIA is only related to VCA IgG or IgM antibody. This study is the first including CLIA in VCA-IgA research [18,19]. Our first study shows that CLIA have better Within-run CV and Total CV.…”
Section: Correlation Among the Six Assaysmentioning