2020
DOI: 10.1109/access.2020.3001197
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of AC Flashover Performance of Snow-Accreted Insulators Under Natural and Artificial Simulation Environments

Abstract: The research and exploration on snow-accreted insulators have been performed in an artificial climate chamber. However, the differences in the distribution, density and compactness of snow accretion under natural and artificial simulation environments cause the flashover mechanism of snowcovered insulators to remain poorly understood. In the present work, a series of flashover tests were carried out on snow-coated glass and silicone rubber insulators in the climate chamber and at Xuefeng Mountain Natural Icing… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 24 publications
0
3
0
Order By: Relevance
“…The icing test in the natural environment is closer to the real icing situation than that in an artificial climate chamber [13, 27]. However, if natural precipitation is used to carry out the insulator icing test in the field, not only the test period is long but also the data obtained are not comparable due to differences in the environmental parameters.…”
Section: Rime Icing On the Insulator Surface In The Fieldmentioning
confidence: 99%
“…The icing test in the natural environment is closer to the real icing situation than that in an artificial climate chamber [13, 27]. However, if natural precipitation is used to carry out the insulator icing test in the field, not only the test period is long but also the data obtained are not comparable due to differences in the environmental parameters.…”
Section: Rime Icing On the Insulator Surface In The Fieldmentioning
confidence: 99%
“…Ice accretion on the surface of insulator is one of the key factors affecting the secure and stable operation of transmission lines. The degradation of electrical performance of the insulators caused by icing and even large-scale blackouts have been reported at home and abroad [1][2][3]. In January and February of 2008, disastrous ice and snow storm severely damaged of China grid in 14 provinces, with direct economic losses more than $16 billion [1].…”
Section: Introductionmentioning
confidence: 99%
“…Some scholars believe that the Chinese people's idea of "valuing economy and ignoring environment" is deeply rooted. Some scholars have proposed to integrate ecological civilization construction into economic and social development [5,6]. He pointed out that human beings should take people first as the principle, regard the ecological environment as a kind of resource rather than a cost, adhere to the scientific and rational use of resources and the environment, and give consideration to both immediate and long-term interests, so as to maximize the development and protection of natural resources.…”
Section: Introductionmentioning
confidence: 99%