2022
DOI: 10.21037/qims-21-328
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of acquisition and iterative reconstruction parameters in abdominal computed tomography-guided procedures: a phantom study

Abstract: Background: Many computed tomography (CT) navigation systems have been developed to help radiologists improve the accuracy and safety of the procedure. We evaluated the accuracy of one CT computer-assisted guided procedure with different reduction dose protocols.Methods: A total of 128 punctures were randomly made by two operators on two different anthropomorphic phantoms. The tube voltage was fixed to 100 kVp. Tube currents (mAs) were defined to obtain 4 dose levels: 180 mAs (D1.00), 90 mAs (D0.50), 45 mAs (D… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(1 citation statement)
references
References 30 publications
0
1
0
Order By: Relevance
“…Radiologically equivalent anthropomorphic phantoms could be a valuable tool for a plethora of applications, since it is possible to replicate human tissues' x-ray characteristics, as well as, to assess various medical imaging systems and techniques. Particularly, a phantom can be used for dose verification (Robinson et al 2016, Alssabbagh et al 2017, Goodall et al 2021, quality assurance (Ehler et al 2014, Gear et al 2016, Madamesila et al 2016, medical imaging devices' settings optimization (Woliner-van der Weg et al 2016, Frandon et al 2021), and surgery planning (Kettenbach et al 2014, Shin et al 2016, and imaging modalities such as cancer diagnosis and imaging techniques optimization (Gear et al 2014, Bliznakova, 2020, Holmes et al 2020, Dukov et al 2022.…”
Section: Introductionmentioning
confidence: 99%
“…Radiologically equivalent anthropomorphic phantoms could be a valuable tool for a plethora of applications, since it is possible to replicate human tissues' x-ray characteristics, as well as, to assess various medical imaging systems and techniques. Particularly, a phantom can be used for dose verification (Robinson et al 2016, Alssabbagh et al 2017, Goodall et al 2021, quality assurance (Ehler et al 2014, Gear et al 2016, Madamesila et al 2016, medical imaging devices' settings optimization (Woliner-van der Weg et al 2016, Frandon et al 2021), and surgery planning (Kettenbach et al 2014, Shin et al 2016, and imaging modalities such as cancer diagnosis and imaging techniques optimization (Gear et al 2014, Bliznakova, 2020, Holmes et al 2020, Dukov et al 2022.…”
Section: Introductionmentioning
confidence: 99%