2018
DOI: 10.1088/1755-1315/113/1/012205
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of airflow-uniformity in different ceiling-diffuser designs with various concentric circles in shrimp freezer using CFD

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 11 publications
1
2
0
Order By: Relevance
“…Configuration of streamlines exiting the side grills of air coolers showed the necessity to address the issue of the special air distributor -deflector which will even the air flow and direct it uniformly towards the periphery of the side rows of pallets. This is in conformity with the results presented in [9].The temperature distribution along the line passing through the center of the row of cages adjacent to the axial line at different heights is presented in Fig 2 and 3.…”
Section: Resultssupporting
confidence: 91%
See 1 more Smart Citation
“…Configuration of streamlines exiting the side grills of air coolers showed the necessity to address the issue of the special air distributor -deflector which will even the air flow and direct it uniformly towards the periphery of the side rows of pallets. This is in conformity with the results presented in [9].The temperature distribution along the line passing through the center of the row of cages adjacent to the axial line at different heights is presented in Fig 2 and 3.…”
Section: Resultssupporting
confidence: 91%
“…boundary conditions, including the initial temperature of the product, the temperature of the cooled air, boundary conditions on the walls, the ceiling and the floor, which allows to take into account the individual features of a particular project. It is also possible to enter parameters that allow to perform a variational calculations, aimed at the determining of optimal designs of air coolers, air deflectors, distributors etc [5,7,9].…”
Section: -D Model Developmentmentioning
confidence: 99%
“…A diffuser with a half cone angle of 70 was found to provide maximum static pressure recovery and exhibit better performance. Uraijaree et al 22) studied the effects of designs of ceiling diffusers with various concentric circles on airflow patterns using computational fluid dynamics simulations software. It was found that a ceiling diffuser with five concentric circles improves airflow quality at the outlet by 13.57% which reduced shortened freezing time.…”
Section: Introductionmentioning
confidence: 99%