Comparison of an infrared anaesthetic agent analyser (Datex-Ohmeda) with refractometry for measurement of isoflurane, sevoflurane and desflurane concentrations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 14 publications
0
2
0
1
Order By: Relevance
“…P E ′CO 2 and isoflurane concentration in these samples were determined using an infrared spectrometer (DX-AJAGA-1 (AGA); Dixtal, Brazil). The anesthetic gas analyzer was calibrated before and during each experiment with room air and three calibration standards containing 0.5, 1.5 and 3% isoflurane (White Martins Gases Industriais SA, Brazil) [ 15 ]. End-tidal isoflurane values were corrected using the linear regression equation generated from the calibration standards; P E ′CO 2 auto-calibration was performed by the infrared spectrometer before and during the study.…”
Section: Methodsmentioning
confidence: 99%
“…P E ′CO 2 and isoflurane concentration in these samples were determined using an infrared spectrometer (DX-AJAGA-1 (AGA); Dixtal, Brazil). The anesthetic gas analyzer was calibrated before and during each experiment with room air and three calibration standards containing 0.5, 1.5 and 3% isoflurane (White Martins Gases Industriais SA, Brazil) [ 15 ]. End-tidal isoflurane values were corrected using the linear regression equation generated from the calibration standards; P E ′CO 2 auto-calibration was performed by the infrared spectrometer before and during the study.…”
Section: Methodsmentioning
confidence: 99%
“…The spectrophotometer was calibrated daily using room air and three standards of known isoflurane concentrations (0.5%, 1.5% and 3.0%) (Isoflurane, N 2 , O 2 ; White Martins Gases Industriais SA, Brazil). Values measured by the spectrophotometer were corrected by means of linear regression based on the calibration values (Rudolff et al 2014).…”
Section: Anesthesia and Instrumentationmentioning
confidence: 99%
“…3), przechodzących przez próbkę powietrza i zbieranych przez detektor. Na tej podstawie odbywa się pomiar ilościowy i jakościowy (wykrywanie rodzaju anestetyku w zależności od długości pochłanianej fali) (44,45).…”
unclassified