1995
DOI: 10.1097/00002341-199506000-00029
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Artifact from Craniomaxillofacial Internal Fixation Devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
29
0
6

Year Published

2001
2001
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(35 citation statements)
references
References 0 publications
0
29
0
6
Order By: Relevance
“…Uma calibração adequada do aparelho e a orientação ao paciente sobre o procedimento a ser realizado devem sempre ser medidas adotadas para diminuir o aparecimento de artefatos e, também, evitar a exposição do paciente a dose de radiação desnecesária por repetição do procedimento 8. Link et al 10 (2000) relataram que existem várias técnicas que tentam diminuir ou eliminar a presença de artefatos em TC de regiões que contenham algum elemento metálico. Eles propuseram uma técnica de reformatação a qual denominaram "Escala Extensa de TC" (EETC) e a aplicaram realizando tomografia computadorizada em vários protocolos (com diferentes espessuras de cortes e intervalo de reconstrução -de 2mm a 5mm) em fêmures secos de suínos submetidos a osteotomias, e posteriores fixações externas usando placas de aço e parafusos corticais com base de cobalto (Vitallium 15 avaliaram os artefatos da TC produzidos por vários elementos metálicos usados em cirurgia crânio--maxilo-facial. Foram avaliados vários materiais e sistemas de fixação basicamente constituídos de titânio, Vitallium e aço inoxidável.…”
Section: Artefatos Metálicosunclassified
“…Uma calibração adequada do aparelho e a orientação ao paciente sobre o procedimento a ser realizado devem sempre ser medidas adotadas para diminuir o aparecimento de artefatos e, também, evitar a exposição do paciente a dose de radiação desnecesária por repetição do procedimento 8. Link et al 10 (2000) relataram que existem várias técnicas que tentam diminuir ou eliminar a presença de artefatos em TC de regiões que contenham algum elemento metálico. Eles propuseram uma técnica de reformatação a qual denominaram "Escala Extensa de TC" (EETC) e a aplicaram realizando tomografia computadorizada em vários protocolos (com diferentes espessuras de cortes e intervalo de reconstrução -de 2mm a 5mm) em fêmures secos de suínos submetidos a osteotomias, e posteriores fixações externas usando placas de aço e parafusos corticais com base de cobalto (Vitallium 15 avaliaram os artefatos da TC produzidos por vários elementos metálicos usados em cirurgia crânio--maxilo-facial. Foram avaliados vários materiais e sistemas de fixação basicamente constituídos de titânio, Vitallium e aço inoxidável.…”
Section: Artefatos Metálicosunclassified
“…Then, we may select , where is a rotation-matrix, translation-vector pair that describes the object in its unknown position according to . In two dimensions, we define the rotation matrix by (4) so it is parameterized by a single rotation angle . The translation vector, , is two-dimensional, for a total of three unknown parameters characterizing the position and orientation of the object.…”
Section: The Deblurring Problem: Definitionmentioning
confidence: 99%
“…For this reason, X-ray tomographic images intended to visualize soft tissues in the vicinity of prosthetic implants, surgical clips, spinal rods, cochlear implants, brachytherapy applicators, etc., are of greatly diminished or no clinical value when formed from projection data by FBP. This difficulty is discussed by Fiala et al [4], Kalender et al [7], DeMan et al [3], Marks and Callen [11], Robertson et al [18], Strumas et al [24], and by many others.…”
Section: Introductionmentioning
confidence: 99%
“…Esses objetos metálicos, quando presentes na área escaneada pela TC, produzem os artefatos metálicos dentários com aspectos de estrias hiperdensas ou do tipo "beam hardening" nas imagens de TC (Fiala et al, 1993;Fiala et al, 1994;Glover et al, 1981;Perrella et al,2010 virtual da cirurgia foi realizada. A média da distância entre os pontos da TC e da superfície óptica 3D foi de 0,1262 ± 0,0301 mm e 0,2671 ± 0,0580 mm, para os modelos de gesso, com e sem restaurações metálicas, respectivamente, sendo estatisticamente significante (p<0,0005).…”
Section: Influência De Artefatos Metálicos Na Tomografia Computadorizadaunclassified
“…. Embora exista evidência de que ambas as técnicas sejam precisas e tenham acurácia, a presença de artefatos metálicos dentários ainda parece interferir com a análise das imagens (Draenert et al, 2007;Katsumata et al, 2006;Holberg et al, 2005;Perrella et al, 2010 (Fiala et al, 1993;Fiala et al, 1994;Glover et al, 1981). Na reconstrução das imagens, os artefatos metálicos dentários podem ser observados como áreas hipodensas (beam hardening), circunscritas por áreas hiperdensas (estrias) com mais de 1000 Unidades Hounsfield (UH) (escala de densidade cinza da TC), que podem ser observadas próximo de qualquer tipo de metal, incluindo implantes de titânio e restaurações metálicas (Draenert et al, 2007;Perrella et al, 2010).…”
Section: Introductionunclassified