2023
DOI: 10.3389/fendo.2023.1161116
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of computed tomography and dual-energy X-ray absorptiometry in the evaluation of body composition in patients with obesity

Abstract: Objectivea) To evaluate the accuracy of the pre-existing equations (based on cm2 provided by CT images), to estimate in kilograms (Kg) the body composition (BC) in patients with obesity (PwO), by comparison with Dual-energy X-ray absorptiometry (DXA). b) To evaluate the accuracy of a new approach (based on both cm2 and Hounsfield Unit parameters provided by CT images), using an automatic software and artificial intelligence to estimate the BC in PwO, by comparison with DXA.MethodsSingle-centre cross-sectional … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
4
0
2

Year Published

2024
2024
2024
2024

Publication Types

Select...
3
2

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 45 publications
0
4
0
2
Order By: Relevance
“…Tissue quality was assessed based on its average Hounsfield Units (HU) value. Standard thresholds were used as follows: −29 to 150 HU for skeletal muscle, −190 to−30 for subcutaneous adipose tissue and−150 to−50 for visceral adipose tissue ( 41 , 42 , 47 ).…”
Section: Methodsmentioning
confidence: 99%
“…Tissue quality was assessed based on its average Hounsfield Units (HU) value. Standard thresholds were used as follows: −29 to 150 HU for skeletal muscle, −190 to−30 for subcutaneous adipose tissue and−150 to−50 for visceral adipose tissue ( 41 , 42 , 47 ).…”
Section: Methodsmentioning
confidence: 99%
“…В одноцентровом перекрестном исследовании, выполненном Palmas F. et al (2023), оценивали точность автоматического программного обеспечения и искусственного интеллекта для анализа CT в диагностике ожирения, по сравнению с DXA, принятым за эталон. Всем пациентам (46 человек с ожирением и 24 -с нормальным ИМТ) была проведена оценка состава тела с помощью DXA и CT на уровне L3.…”
Section: компьютерная томография (Computed Tomography Ct)unclassified
“…В результате, между тремя моделями и DXA были получены значимые корреляции. Модель 3 показала самую сильную корреляцию с DXA (r= 0,926; ДИ 95%: 0,835-0,968; р<0,001), а также наилучшее согласие, основанное на графиках Бланда-Альтмана [47].…”
Section: компьютерная томография (Computed Tomography Ct)unclassified
“…Currently, body mass index (BMI) continues to serve as a categorical diagnostic measure for obesity. However, BMI has notable drawbacks as it does not offer insights into body composition (BC) or the metabolic status of individuals [4,5]. In this way, new methods, as muscle ultrasound (MUS), should be introduced into clinical practice to assess the BC of these patients, especially if they are candidates for bariatric surgery (BS), since weight loss caused by BS leads to changes in the BC.…”
Section: Introductionmentioning
confidence: 99%
“…Nonetheless, DEXA lacks the ability to provide information about specific muscle groups, thus failing to address regional sarcopenia. Additionally, accessibility to DEXA is limited in many clinics, and it is not routinely performed except for bone density assessment [5,13,14]. Among the numerous methods available for assessing muscle mass, MUS is becoming increasingly recognized as a valuable tool in clinical settings, being a simple, real-time, noninvasive, radiationfree, low-cost, and easily transportable technique.…”
Section: Introductionmentioning
confidence: 99%