2018
DOI: 10.1016/j.ifacol.2018.11.711
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Current-Limiting Strategies of Virtual Synchronous Generator Control during Fault Ride-Through

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 12 publications
0
4
0
Order By: Relevance
“…However, a current-controlled synchronverter is the same as a current source, providing voltage and frequency support for the system. In [15], a voltage-controlled synchronverter technique is proposed to alleviate the shortcomings of the current-controlled synchronverter. The goal of voltage-controlled synchronverter techniques is to simulate the rotor inertia and system frequency modulation characteristics of SG in frequency control to improve the system's frequency stability [16].…”
Section: Background Studymentioning
confidence: 99%
See 1 more Smart Citation
“…However, a current-controlled synchronverter is the same as a current source, providing voltage and frequency support for the system. In [15], a voltage-controlled synchronverter technique is proposed to alleviate the shortcomings of the current-controlled synchronverter. The goal of voltage-controlled synchronverter techniques is to simulate the rotor inertia and system frequency modulation characteristics of SG in frequency control to improve the system's frequency stability [16].…”
Section: Background Studymentioning
confidence: 99%
“…At present, most scholars seldom present the grid-connection stability and mostly use the small-signal model. Researchers [15] have discussed the smallsignal model adopted to study the stability of a single machine incorporated into the power grid. Some [16] studied the situation of two machines connected to a microgrid under small-signal interference and also studied the influence of the change in the control parameters and circuit parameters on the stability of the system.…”
Section: Virtual Synchronous Generatormentioning
confidence: 99%
“…Conclusively, the FCS-MPC scheme's benefits are presented, including simple implementation, straightforward control law, and fast dynamic response. The conventional FCS-MPC-based DG system, however, has been designed for a system with simple inductive filters (L filters) or inductive 335 capacitance filters (LC filters), e.g., presented in [13]- [14]. On the other hand, to achieve sinusoidal grid currents with low distortions, an LCL filter is an attractive alternative with relatively lower cost compared with conventional LC filters [16]- [17].…”
Section: Introductionmentioning
confidence: 99%
“…Recently, several active damping solutions based on multivariable control for grid-connected rectifiers have been proposed [22]- [24]. The concept of FCS-MPC-based multivariable control can also be applied to grid-connected voltage source inverters (VSIs), as suggested in [13]- [15]. Nevertheless, in the referred works, the purpose of a filter current control inclusion was to achieve overcurrent prevention.…”
Section: Introductionmentioning
confidence: 99%