Comparison of Cyclic Fatigue Resistance of Novel TruNatomy Files with Conventional Endodontic Files: An In Vitro SEM Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
1
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 24 publications
0
1
0
Order By: Relevance
“…[ 37 38 ] The cause of this decreased fatigue resistance of NeoEndo Flex could be attributed to the design of these files, no radial land with sharp cutting edges and triangular cross-section that may hasten the screwing effect hence early breakage. [ 39 40 ] The cross-sectional design influences the fatigue resistance of NiTi rotary file as it determines the bulk of metal mass, thus making the file stiffer. Previous studies reveal that triangular cross-sections have less metal mass and have increased fatigue resistance than square cross-sectional design, which are in disagreement with the results of the present study.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…[ 37 38 ] The cause of this decreased fatigue resistance of NeoEndo Flex could be attributed to the design of these files, no radial land with sharp cutting edges and triangular cross-section that may hasten the screwing effect hence early breakage. [ 39 40 ] The cross-sectional design influences the fatigue resistance of NiTi rotary file as it determines the bulk of metal mass, thus making the file stiffer. Previous studies reveal that triangular cross-sections have less metal mass and have increased fatigue resistance than square cross-sectional design, which are in disagreement with the results of the present study.…”
Section: Discussionmentioning
confidence: 99%
“…This observation revealed that the tested instruments were correctly positioned in canal curvature and demonstrated that the similar stresses were induced during cyclic fatigue testing. [ 39 43 ] Therefore, the point of maximum stress concentration was located 3.5–4 mm from the tip of the each NiTi rotary file in the apical one-third of the curved root canal. [ 44 ]…”
Section: Discussionmentioning
confidence: 99%
“…had standard deviation of 13.35, 62.81, and 165.02 for PG, HEDM, and TN. [ 23 24 ] This variance highlights the lack of standardization in cyclic fatigue tests, possibly due to fabrication quality variation of NiTi instruments and testing methodology discrepancies.…”
Section: Discussionmentioning
confidence: 99%
“…The TruNatomy system, one notable minimally invasive file system, was reported to have increased cyclic fatigue resistance using a thin-shaft and heat-treated alloy [20]. Reddy et al [38] reported that the TN system had better fatigue resistance than the ProTaper Gold system, made of a gold alloy, although Elnaghy et al [39] reported that TN showed a lower fatigue resistance than the HyFlex CM instruments (DS Dental) made of CM-wire [19,38,39]. These findings might result from the difference in heat treatment as well as the geometric characteristics [35].…”