2001
DOI: 10.1007/s002160100924
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of denuder and impinger sampling for determination of gaseous toluene diisocyanate (TDI)

Abstract: An air-sampling method employing denuders coated inside with a chemisorptive stationary phase has been evaluated for analysis of the hazardous gaseous 2,4 and 2,6 isomers of toluene diisocyanate (TDI). The denuder stationary phase consisted of polydimethylsiloxane (SE-30) to which dibutylamine (DBA) was added as a reagent for derivatization of TDI. The accuracy and precision of sampling by means of denuders were shown to differ only slightly from those of the established impinger method. The denuder method was… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
15
0
1

Year Published

2003
2003
2008
2008

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 0 publications
0
15
0
1
Order By: Relevance
“…The study was applied to generated aerosols of the highly reactive 4,4 0 -MDI, and the performance of the system was evaluated in the laboratory by comparison with impinger sampling. In two earlier studies, the denuder tube has been evaluated, without the filter assembly, for sampling vapour of toluene diisocyanate (TDI) isomers 20 and a mixture of TDI, hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI) vapour. 21 Experimental Chemicals Toluene (499.8%), acetonitrile (499.7%) and dichloromethane (for organic trace analysis) were purchased from Merck (Darmstadt, Germany), toluene (analytical grade) from Scharlau Chemie (Barcelona, Spain) and pentane (analytical reagent) from Lab-Scan Ltd (Dublin, Ireland).…”
Section: Sampling Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The study was applied to generated aerosols of the highly reactive 4,4 0 -MDI, and the performance of the system was evaluated in the laboratory by comparison with impinger sampling. In two earlier studies, the denuder tube has been evaluated, without the filter assembly, for sampling vapour of toluene diisocyanate (TDI) isomers 20 and a mixture of TDI, hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI) vapour. 21 Experimental Chemicals Toluene (499.8%), acetonitrile (499.7%) and dichloromethane (for organic trace analysis) were purchased from Merck (Darmstadt, Germany), toluene (analytical grade) from Scharlau Chemie (Barcelona, Spain) and pentane (analytical reagent) from Lab-Scan Ltd (Dublin, Ireland).…”
Section: Sampling Methodsmentioning
confidence: 99%
“…The generating apparatus was the same as that used for TDI in an earlier study. 20 According to results obtained using the impinger system, the concentration generated was 0.3 mg m À3 (CV ¼ 14%, n ¼ 3). Both the denuder and the impinger were connected to a filter.…”
Section: Impinger Samplingmentioning
confidence: 98%
“…The generation chamber used has been described earlier [22]. The atmosphere generated was approximately 24 µg m -3 (3 ppbv) of gaseous TDI, 38 µg m -3 (5 ppbv) of gaseous HDI and 17 µg m -3 (2 ppbv) of gaseous IPDI, giving a total of 79 µg m -3 (10 ppbv) of isocyanates.…”
Section: Generation Of Tdi/hdi/ipdi-atmospherementioning
confidence: 99%
“…4 mm) is somewhat smaller compared to the annular denuder sampler used by Rando et al (240 mm, 24 mm). We have previously described and evaluated this method for gaseous toluene diisocyanate (TDI) [22]. In this study the evaluation is expanded to include a mixture of three common gaseous diisocyanates, TDI, hexamethylene diisocyanate (HDI) and isophorone diisocyanate (IPDI), at individual concentrations near or slightly lower than the 8-hour Swedish OEL of 5 ppbv (34-46 µg m -3 ).…”
Section: Introductionmentioning
confidence: 99%
“…(6) R52, R53 -Nocivo para os organismos aquáticos Nordqvist (2001) Figura 10 -Tipos de emendas longitudinais (a) emenda de topo, (b) emenda bisselada, (c) emenda dentada horizontal e (d) emenda dentada vertical Fonte: Macedo (1996) Figura 11 -Exemplo de emenda dentada (finger-joint) utilizada em MLC (d) Colagem das peças: O processo de colagem, tipo de adesivo, pressão são fatores que podem interferir na qualidade e durabilidade do produto final. Os principais tipos de adesivos utilizados são fenol-formaldeido e resorcinolformaldeído.…”
Section: R53unclassified