2019
DOI: 10.1016/j.ab.2019.05.012
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of different label-free imaging high-throughput biosensing systems for aptamer binding measurements using thrombin aptamers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…Details are given in [414]; company links are provided in [415]. The second study compares Biacore 3000, Octet RED96, IBIS MX96, and 2 imaging RIfS instruments [416]. Some instruments allow multiplex measurements (less than 100 spots in parallel), only for the imaging iRIfS more than 1000 spots can be measured in parallel.…”
Section: Detection Methods Reviewed and Comparedmentioning
confidence: 99%
“…Details are given in [414]; company links are provided in [415]. The second study compares Biacore 3000, Octet RED96, IBIS MX96, and 2 imaging RIfS instruments [416]. Some instruments allow multiplex measurements (less than 100 spots in parallel), only for the imaging iRIfS more than 1000 spots can be measured in parallel.…”
Section: Detection Methods Reviewed and Comparedmentioning
confidence: 99%
“…One obtains the association constant K A = 8 and 14 in Supplementary information) and/or spatial heterogeneity of the ligand sites to be approached by ligate which becomes significant as ligand sites approach saturation [14]. Furthermore, a study of 2019 found out that different measurement systems can deviate up to a factor of 20 for the same analyte [15]. Considering this, variations in determining K A with different setups are more than expectable.…”
Section: Binding Interaction Testmentioning
confidence: 99%
“…Recently, biolayer interferometry (BLI) has been considered as one of the most promising techniques for optical fiber-based, label-free, and real-time detection of biomolecular interactions [ 79 , 80 , 81 , 82 , 83 , 84 , 85 , 86 , 87 , 88 , 89 , 90 , 91 , 92 , 93 ]. BLI includes two reflective surfaces forming an FPI created by a reference layer at an optical fiber tip and the surface of immobilized bioreceptors as shown in Figure 12 [ 90 ].…”
Section: Fabry-perot Interferometer (Fpi)-based Biosensorsmentioning
confidence: 99%
“…A detector measures the reflectance spectrum in real-time, enabling binding kinetics analyses. BLI has been employed in a wide range of biosensing applications from the study and development of drugs and vaccines [ 81 , 83 ] to the detection of various biomolecules [ 85 , 86 , 87 , 89 , 91 , 92 , 93 , 94 ].…”
Section: Fabry-perot Interferometer (Fpi)-based Biosensorsmentioning
confidence: 99%