Comparison of experimental and calculated calibration coefficients for a high sensitivity ionization chamber

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 30 publications
0
7
0
Order By: Relevance
“…However, as such tools often provide limited output data; this may complicate the subsequent uncertainty evaluation. mixtures of argon and xenon [28], or else nitrogen). The situation is even more complicated for beta emitters because of the continuous energy spectrum.…”
Section: Siric Methodmentioning
confidence: 99%
See 2 more Smart Citations
“…However, as such tools often provide limited output data; this may complicate the subsequent uncertainty evaluation. mixtures of argon and xenon [28], or else nitrogen). The situation is even more complicated for beta emitters because of the continuous energy spectrum.…”
Section: Siric Methodmentioning
confidence: 99%
“…Therefore a very good knowledge of the chamber characteristics and its implementation in the code are needed. The geometric model can be implemented in the simulation using the manufacturer's specifications or dra wings and also using radiographs directly taken on the chamber itself [23,28].…”
Section: Siric Methodmentioning
confidence: 99%
See 1 more Smart Citation
“…The chamber is housed in a locally made shielding in order to reduce the background. The PENELOPE simulation model of this chamber (geometry and sample-to-detector configuration) has been well-validated through different comparisons and for several gamma-emitting radionuclides (Amiot et al, 2012). The geometry used in our work is shown in Fig.…”
Section: Description Of the Simulationsmentioning
confidence: 99%
“…), and the shielding around (Ceccatelli et al, 2007;Kryeziu et al, 2007;Thiam et al, 2016). Generally, ICs are well adapted for solutions of gamma-emitting radionuclides (Amiot et al, 2012;Zimmerman and Judge, 2007) but can also be used for high-energy beta-emitting radionuclides such as 90 Y, although such measurements are more challenging (Pearce et al, 2007;Fenwick et al, 2014). In these cases, the IC response strongly depends on the transport of electrons in the radioactive solution and surroundings.…”
Section: Introductionmentioning
confidence: 99%