Comparison of Fast Peritoneal Equilibration Tests with 1.36 and 3.86% Dialysis Solutions

Abstract: At present dialysis solutions with different glucose concentrations are used for the peritoneal equilibration test (PET) and Fast-PET in peritoneal dialysis (PD). We compared the results of two Fast-PETs, using 1.36 and 3.86% solutions sequentially in 30 patients on PD treatment, to obtain information on peritoneal transport (D/P-4 h) and ultrafiltration rates. Creatinine, phosphorus and urea D/P-4 h in the two Fast-PETs were not statistically different, unlike those for potassium, β2-microglobulin … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0

Year Published

2000
2000
2023
2023

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(18 citation statements)
references
References 5 publications
0
18
0
Order By: Relevance
“…There is no meaningful difference in the estimation of PSTR (specifically D/P creatinine at 4 h) between the different glucose concentrations. 44,[98][99][100][101] Indeed, differences such as there are, are within the reproducibility of the test, typically a ratio value of 0.1, which is no greater than the betweencentre variation in this measurement already referred to.…”
Section: Measuring Pstr: the Peritoneal Equilibration Test Pet (Undementioning
confidence: 99%
“…There is no meaningful difference in the estimation of PSTR (specifically D/P creatinine at 4 h) between the different glucose concentrations. 44,[98][99][100][101] Indeed, differences such as there are, are within the reproducibility of the test, typically a ratio value of 0.1, which is no greater than the betweencentre variation in this measurement already referred to.…”
Section: Measuring Pstr: the Peritoneal Equilibration Test Pet (Undementioning
confidence: 99%
“…The 400 mL limit is based on sparse data from literature [63,64] and clinical data of patients who fulfil this criterion. A cause for ultrafiltration failure could be identified in >95% of these patients [52].…”
Section: Definition and Detection Of Ultrafiltration Failurementioning
confidence: 99%
“…Also, in patients with ultrafiltration failure, the PET-test may fail to explain the underlying mechanism. Therefore, some adaptations, such as the use of a 3.86% instead of a 2.27% glucose solution and the evaluation of sodium sieving during the PET-test, have been proposed (69). Peritoneal membrane characteristics can also be described with the use of specialized software, using different models for data collection and calculation of the peritoneal transport of solutes and fluid.…”
Section: Other New Technological Innovations In Pdmentioning
confidence: 99%