2009
DOI: 10.1111/j.1467-2995.2009.00484.x
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of femoral and auricular arterial blood pressure monitoring in pigs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 16 publications
(7 citation statements)
references
References 14 publications
0
7
0
Order By: Relevance
“…In pigs, auricular and femoral SAP, MAP, and DAP measurements were very similar to each other across a wide measurement range (Bass et al. ). A previous study in three isoflurane anesthetized rabbits reported SAP on average 31 mmHg lower, MAP 9 mmHg lower and DAP 1 mmHg higher when compared to pressures measured in the carotid artery (Imai et al.…”
Section: Discussionmentioning
confidence: 79%
“…In pigs, auricular and femoral SAP, MAP, and DAP measurements were very similar to each other across a wide measurement range (Bass et al. ). A previous study in three isoflurane anesthetized rabbits reported SAP on average 31 mmHg lower, MAP 9 mmHg lower and DAP 1 mmHg higher when compared to pressures measured in the carotid artery (Imai et al.…”
Section: Discussionmentioning
confidence: 79%
“…Indirect BP measurement has been widely applied to monitor BP in animals due to its convenience and non-invasiveness. However, in agreement of ACVIM guideline, validation of indirect BP measurement method is necessary to prevent misinterpretation of the anesthetized patient's condition [2,3]. Therefore, the present study focused on the validation of the agreement between direct and indirect BP measurements in the minipigs under different postures, in accordance with ACVIM guideline.…”
Section: Discussionmentioning
confidence: 93%
“…Another less serious problem associated with transfemoral access is that repeat angiography is not straightforward due to anatomical disarrangement and surgical occlusion of the femoral artery resulting from the initial transfemoral approach. In comparative studies on auricular and femoral artery approaches to cardiovascular experimentation (3), pressure monitoring (10), and hepatic angiography (5), the transauricular arterial access has been reported to be as good as or better than the femoral approach in terms of reducing the time to complete the procedure. Carotid angiography of the right side with forceful injection of contrast media into the left auricular artery has been reported in multiple follow-up studies to be straightforward in a rabbit aneurysm model (2).…”
Section: Discussionmentioning
confidence: 99%