2022
DOI: 10.1016/j.ajic.2022.02.009
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of filtration efficiency and respiratory resistance of COVID-19 protective masks by multi-national standards

Abstract: Background Face masks from worldwide satisfy different standards during the COVID-19 pandemic, which led to the public misunderstanding of the concepts. Methods We systematically evaluated the quality of face masks provided by different companies according to multi-national standards, including EN 149-2001+A1: 2009, GB 2626-2019 and NIOSH 42 CFR Part 84-2019, focusing particularly on the particulate filtration efficiency (PFE) and respiratory resistance performance. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(3 citation statements)
references
References 25 publications
1
2
0
Order By: Relevance
“…According to national standards, the filter layer of medical surgical masks should be around 0.025−0.05 mm. 35,36 As shown in Figure S3, the thickness of the prepared filter layer is around 30−40 μm, which is in line with the standard of melt-blown cloth for medical surgical masks. The TGA curves in Figure S4 show that these fiber membranes have high thermal stability and further verify the loading of ZIF-8@CCM nanoparticles.…”
Section: Resultssupporting
confidence: 74%
“…According to national standards, the filter layer of medical surgical masks should be around 0.025−0.05 mm. 35,36 As shown in Figure S3, the thickness of the prepared filter layer is around 30−40 μm, which is in line with the standard of melt-blown cloth for medical surgical masks. The TGA curves in Figure S4 show that these fiber membranes have high thermal stability and further verify the loading of ZIF-8@CCM nanoparticles.…”
Section: Resultssupporting
confidence: 74%
“…To minimize breathing resistance, the face mask must be air-permeable without compromising its effectiveness as a particle filter. Breathing resistance is measured by inhalation and exhalation following EN 149:2009, and it is a standard criterion for evaluating respirators such as FFR, FFP1-3, N95, and KN95 (Wang et al, 2022). The assessment must begin with mask conditioning, specifically heating and cooling cycles at 70 °C that extend up to 24 h then -30 °C for another 24 h respectively, with at least 4 h of rest interval between the two phases.…”
Section: Breathing Resistancementioning
confidence: 99%
“…Prior research suggests N95 respirators offer higher degrees of protection, resulting in fewer observed respiratory and influenza-like illnesses, compared to surgical options [12,13]. Currently, numerous different standards exist worldwide, delineating testing procedures for essential factors, including fluid resistance, breathability, bacterial filtration efficiency (BFE), particle filtration efficiency (PFE), and other parameters crucial for assessing the quality of face masks [14,15]. This underscores the significance of studying the effects of various masks, as an enduring and critical subject of research.…”
Section: Introductionmentioning
confidence: 99%