2017
DOI: 10.1016/j.radphyschem.2017.02.029
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Flattening Filter (FF) and Flattening-Filter-Free (FFF) 6 MV photon beam characteristics for small field dosimetry using EGSnrc Monte Carlo code

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
12
0

Year Published

2018
2018
2025
2025

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 18 publications
(13 citation statements)
references
References 59 publications
1
12
0
Order By: Relevance
“…Most previous works reported an increase in dose rate by factor of 2 [3637] who worked on Siemens ONCOR Avant-Garde and Siemens Primus linacs, respectively. For the other vendors, recently Sangeetha et al [38] reported a relative dose rate of 2.52 (2.60) for the 10×10 cm 2 (20×20 cm 2 ) field for a Varian 600C/D and Dalaryd et al [39], observed that the dose rate of the FFF beams increased by a factor of 2.23 for an ElektaPrecise. Notably, the values for our Siemens Artiste were larger than previous ones with dose rate of 2.8 (2.96) for the 10×10 cm 2 (20×20 cm 2 ) fields.…”
Section: Discussionmentioning
confidence: 99%
“…Most previous works reported an increase in dose rate by factor of 2 [3637] who worked on Siemens ONCOR Avant-Garde and Siemens Primus linacs, respectively. For the other vendors, recently Sangeetha et al [38] reported a relative dose rate of 2.52 (2.60) for the 10×10 cm 2 (20×20 cm 2 ) field for a Varian 600C/D and Dalaryd et al [39], observed that the dose rate of the FFF beams increased by a factor of 2.23 for an ElektaPrecise. Notably, the values for our Siemens Artiste were larger than previous ones with dose rate of 2.8 (2.96) for the 10×10 cm 2 (20×20 cm 2 ) fields.…”
Section: Discussionmentioning
confidence: 99%
“…On the other hand, the flattening filter is replaced with other filter material to maintain the signal received by monitor chambers on FFF linac design [ 4 ]; however, the filter design is not provided by manufacturers. Thus, many researchers have been predicted and simulated design of the FFF linac head especially on the flattening filter replacement material [ 5 - 7 ]. Several studies have been conducted to measure and compare 6MV photon beam characteristics, both on Monte Carlo simulations and measurements.…”
Section: Introductionmentioning
confidence: 99%
“…The dose verification of single square-field and multifield irradiation of IMRT was also performed by the 3D gel dosimeters [15]. Nevertheless, the homogeneous dose delivery revealed disagreement with TPS when using small-field irradiation techniques [16,17]. The flattening filter free (FFF) beam irradiation increased the dose conformity and further reduced the treatment delivery time in radiosurgery by removing the flattening filter [1,18,19].…”
Section: Introductionmentioning
confidence: 99%