1994
DOI: 10.1016/0021-9673(94)80438-9
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of four methods for the determination of polycyclic aromatic hydrocarbons in airborne particulates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0
2

Year Published

1997
1997
2016
2016

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 27 publications
(12 citation statements)
references
References 17 publications
0
10
0
2
Order By: Relevance
“…57 Por exemplo, na determinação de HPA e quinonas em cinzas o uso de Soxhlet foi mais eficiente do que a sonicação, 58 enquanto que, quando a matriz é MPA, a sonicação é mais eficaz. 59 Quando comprovadamente não ocorre a decomposição do analito, o uso de ultrassom apresenta vantagens tais como reprodutibilidade, utilização de uma ampla faixa de tamanho de amostra, baixo consumo de energia, reduzido uso de solventes e rapidez no processamento da amostra. 1 Outra técnica que pode ser utilizada é a extração acelerada por solvente (ASE) que foi desenvolvida para o isolamento de HPA.…”
Section: Extração De Quinonasunclassified
“…57 Por exemplo, na determinação de HPA e quinonas em cinzas o uso de Soxhlet foi mais eficiente do que a sonicação, 58 enquanto que, quando a matriz é MPA, a sonicação é mais eficaz. 59 Quando comprovadamente não ocorre a decomposição do analito, o uso de ultrassom apresenta vantagens tais como reprodutibilidade, utilização de uma ampla faixa de tamanho de amostra, baixo consumo de energia, reduzido uso de solventes e rapidez no processamento da amostra. 1 Outra técnica que pode ser utilizada é a extração acelerada por solvente (ASE) que foi desenvolvida para o isolamento de HPA.…”
Section: Extração De Quinonasunclassified
“…Glass beads were covered with small portions of extract solution (6 mg of extract dissolved in CH2C12) and a stream of nitrogen was bubbled through the beads so that no material eluted through the bottom of the bead bed [4][5]. The prepared bed was put into an empty column and coupled to the previously moistened SPE-CN column and then both were eluted with n-hexane.…”
Section: Procedures C: Spe-cn and Spe-sioh (Figure Lc)mentioning
confidence: 99%
“…7,8,9 Analytical techniques used for PAHs determination are both gas and liquid chromatography with different detection systems. 10,11 The official method 8 employs gas chromatography with flame ionization detector (FID) and for the absence of selectivity and sensitivity in this detection system prior to analysis an intermediate clean-up step by thin layer chromatography is required. A mass spectrometer operating in selected ions monitoring (MS-SIM) improves selectivity and sensitivity, but it is not selective for isomers with identical mass spectra.…”
Section: Introductionmentioning
confidence: 99%
“…The first concerns PAHs recovery evaluation from particulate sample on filter. This evaluation does not require spiked filters 10,12 and is based on the recovery trend obtained from sample subsequent extractions. The second improvement comes from using FLD on line spectra detector.…”
Section: Introductionmentioning
confidence: 99%