2018
DOI: 10.1097/md.0000000000011305
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of free-hand fluoroscopic guidance and electromagnetic navigation in distal locking of tibia intramedullary nails

Abstract: BackgroundIt is challenges for surgeon to position the distal locking screw of a tibia intramedullary nail. The traditional free-hand (FH) technique is related to the proficiency of surgeons and has a long learning curve. Furthermore, the radiation dose and the accuracy of screw placement should be taken into account. The new technology, the electromagnetic navigation system (ET), which is a radiation-free way to locate the position of the drill bit. The purpose of our study is to evaluate the results of the E… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 26 publications
0
7
0
Order By: Relevance
“…In our study, operating surgeon decision is the main say to ask for sequential imaging at different steps of nailing from the entry of guide wire, fracture reduction, serial reaming of the canal, nail measurement, intramedullary nail insertion (reamed/unreamed) (Court-Brown et al, 1996;Leroux et al, 2015) two proximal and two distal locking screws done with the jig and free hand technique (Wang et al, 2018;Whatling and Nokes, 2006), intramedullary ixation with two proximal and two distal locking screws for tibia and femur shaft fractures only were considered with inbuilt static and dynamic options.…”
Section: Resultsmentioning
confidence: 99%
“…In our study, operating surgeon decision is the main say to ask for sequential imaging at different steps of nailing from the entry of guide wire, fracture reduction, serial reaming of the canal, nail measurement, intramedullary nail insertion (reamed/unreamed) (Court-Brown et al, 1996;Leroux et al, 2015) two proximal and two distal locking screws done with the jig and free hand technique (Wang et al, 2018;Whatling and Nokes, 2006), intramedullary ixation with two proximal and two distal locking screws for tibia and femur shaft fractures only were considered with inbuilt static and dynamic options.…”
Section: Resultsmentioning
confidence: 99%
“…Furthermore, as extensively demonstrated in human medicine (REF computer assisted vs freehand), computer assisted-surgeries could be more accurate and faster than free-hand techniques when performing osteotomy 13 fracture fixation 17 , joint replacement surgery 11 and vertebral screw placement as well 5 .…”
Section: Discussionmentioning
confidence: 95%
“…effectiveness and safety of the laser device with freehand technique. 7,25 According to literature, the freehand positioning of the distal locking screw takes about 7-15 minutes 10 . It takes more operative and radiation exposure time for novice surgeons.…”
Section: Discussionmentioning
confidence: 99%
“…However, these technologies (including traditional freehand technique 7 ) still have some limitations, such as inaccurate positioning, low first success rate, high demand for expensive equipment, long learning curve of surgeons. [6][7][8][9][10][11][12][13] Based on the above problems, our team designed a laser guiding navigation device based on G-arm and a matching positioning technique by taking advantage of the characteristics of the accuracy and stability of laser. The device has the advantages of easy installation, accurate positioning, no radiation exposure during operation, and is easy to master.…”
Section: Introductionmentioning
confidence: 99%