2011
DOI: 10.1007/s10554-011-9828-z
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of global left ventricular function using 20 phases with 10-phase reconstructions in multidetector-row computed tomography

Abstract: To compare the measurement of global left-ventricular (LV) function parameters of 64-slice multidetector-row computed tomography (MDCT) between 20- and 10-reconstruction phases. Fifty five patients with suspected or known coronary artery disease underwent 64-slice MDCT. LV end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV), and ejection fraction (EF) were measured from MDCT data sets using threshold-based volume segmentation and reconstruction at every 5% (20 phases) and 10% (10 phases) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
1
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 31 publications
0
1
0
1
Order By: Relevance
“…The use of 5% instead of 10% increments has been described as yielding a higher accuracy and a more favorable comparison with MR imaging (3,22,23). However, recent comparative studies demonstrated that, although results were different with 5% intervals than with 10% intervals, the differences were not significant (24,25), so that phase reconstruction at 10% intervals is sufficient.…”
Section: End-systolic and End-diastolic Phase Selectionmentioning
confidence: 99%
“…The use of 5% instead of 10% increments has been described as yielding a higher accuracy and a more favorable comparison with MR imaging (3,22,23). However, recent comparative studies demonstrated that, although results were different with 5% intervals than with 10% intervals, the differences were not significant (24,25), so that phase reconstruction at 10% intervals is sufficient.…”
Section: End-systolic and End-diastolic Phase Selectionmentioning
confidence: 99%
“…[20] MDBT ile kardiyak fonksiyonların değerlendirilmesinde 10 faz (%10'luk intervallerden oluşan) ve 20 faz (%5'lik intervallerden oluşan) rekonstrüksiyon-ları birbirleriyle karşılaştırdıklarında, 10 faz ile yapılan incelemelerde sol ventrikül EF değerle-rinin kardiyak MR ve 3 boyutlu ekokardiyografiye göre daha düşük olduğunu belirtmişlerdir. Diğer taraftan, 10 faz veya 20 faz kullanılarak yapılan ölçümlerde ortaya çıkan farklılığın klinik olarak çok anlamlı olmadığını, 10 faz kullanıldığında görüntülerin daha kısa bir zamanda işlenebilmesi nedeniyle sol ventrikül volümü ve EF hesaplamasında tercih edilebileceğini belirten çalışmalar da mevcuttur [21].…”
Section: Kardiyak Fonksiyonların Değerlendirilmesiunclassified