2016
DOI: 10.21577/0103-5053.20160236
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of ICP OES and LIBS Analysis of Medicinal Herbs Rich in Flavonoids from Eastern Europe

Abstract: Essential and toxic metals were determined in eighteen samples of medicinal herbs from Poland, Lithuania and Serbia by means of laser-induced breakdown spectroscopy (LIBS) and inductively coupled plasma optical emission spectrometry (ICP OES). Calcium, K and Mg concentrations were obtained in % (m/m) and other metals (Na, Co, Cu, Fe, Mn, Ni, Zn, Cd, Cr and Pb) in mg kg -1. The fact that the herb samples analyzed belonged to specific plant species and represented different morphological plant parts explained th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
31
0
3

Year Published

2017
2017
2019
2019

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 29 publications
(35 citation statements)
references
References 20 publications
1
31
0
3
Order By: Relevance
“…Esses parâmetros comumente são otimizados através de planejamento experimental a fim de obter uma condição ótima ou de compromisso. [80][81][82][83][84] Em trabalho proposto por Castro e Pereira-Filho, 43 a LIBS foi usada para análise direta de ligas metálicas, e as condições instrumentais (energia do pulso do laser, tempo de atraso e área do pulso) foram otimizadas utilizando planejamento do tipo Doehlert. No trabalho proposto por Andrade e Pereira-Filho, 85 a LIBS foi empregada para análise direta de fertilizantes.…”
Section: Libs E Quimiometriaunclassified
“…Esses parâmetros comumente são otimizados através de planejamento experimental a fim de obter uma condição ótima ou de compromisso. [80][81][82][83][84] Em trabalho proposto por Castro e Pereira-Filho, 43 a LIBS foi usada para análise direta de ligas metálicas, e as condições instrumentais (energia do pulso do laser, tempo de atraso e área do pulso) foram otimizadas utilizando planejamento do tipo Doehlert. No trabalho proposto por Andrade e Pereira-Filho, 85 a LIBS foi empregada para análise direta de fertilizantes.…”
Section: Libs E Quimiometriaunclassified
“…Several different food matrices are currently analyzed in our research group using this instrument and the conditions are well stablished with several examples obtained in the last 3 years. 12,28,44 In this way, Table 1 shows an instrumental condition that permitted good reproducibility, no signal saturation for major constituents and high analytical frequency.…”
Section: Libs Instrumentation and Solid Sample Preparationmentioning
confidence: 99%
“…Reference material with certified values concentration for masses in this range or lower are not commercially available. 38,44,45 Direct solid analysis also presents difficulties, such as the data reproducibility related to the ablation process, formation of the plasma, microheterogeneity and matrix effects, which in some cases can be minimized applying several types of normalizations or standardization on the raw data. 46 In the present study, a simple and fast method for the direct analysis of powdered samples of dietary supplements by LIBS to determine Ca, Mg and K was applied and discussed.…”
Section: Introductionmentioning
confidence: 99%
“…20,21 The optimization of instrumental conditions was carried out by performing 15 experiments in one sample and by simultaneously monitoring the three major elements. Laser pulse energy (30-80 mJ), delay time (0-2 µs), and spot size (50-150 µm) were varied.…”
Section: Libs: Optimization and Analysismentioning
confidence: 99%