Comparison of incision size and intraocular lens performance after implantation with three preloaded systems and one manual delivery system

Abstract: PurposeTo compare corneal incision size and intraocular lens (IOL) performance/behavior following implantation with the following delivery systems: system U (UltraSert®), system S (Hoya iSert® 250/251), system T (Tecnis® iTec), and a manual system (Monarch® III Delivery System).SettingSix study sites (four in Spain and two in France).DesignProspective, multicenter, parallel-group, randomized, subject-masked, postmarket clinical study.Materials and methodsSubjects were enrolled based on predetermined inclusion/… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
18
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(23 citation statements)
references
References 29 publications
1
18
0
2
Order By: Relevance
“…Indeed, cases of trapped trailing haptics (7-19%) and uncontrolled unfolding of the leading haptic (13%) have been reported in currently available preloaded delivery systems. 11,12,15 Therefore, the anticipated reductions in case time for the preloaded IOL delivery system in the current study may be explained by a combination of these factors, suggesting that this system provides efficient and controlled delivery of the IOL while maintaining an acceptable enhanced safety profile during cataract surgery.…”
Section: Discussionmentioning
confidence: 84%
See 3 more Smart Citations
“…Indeed, cases of trapped trailing haptics (7-19%) and uncontrolled unfolding of the leading haptic (13%) have been reported in currently available preloaded delivery systems. 11,12,15 Therefore, the anticipated reductions in case time for the preloaded IOL delivery system in the current study may be explained by a combination of these factors, suggesting that this system provides efficient and controlled delivery of the IOL while maintaining an acceptable enhanced safety profile during cataract surgery.…”
Section: Discussionmentioning
confidence: 84%
“…Previous nonclinical and clinical studies evaluating other automated/preloaded IOL delivery systems have also reported similar small incision sizes that ranged from 2.2 to 2.6 mm for most cases. 11,18,[20][21][22][23][24] The use of smaller incision sizes may be beneficial during IOL implantation as they can promote faster wound healing and reduce the risk of astigmatism, inflammation, and postoperative endophthalmitis. 2,[25][26][27] In the current study, surgeons reported an estimated mean time-savings per procedure of approximately 1 min when compared with other non-preloaded delivery systems.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Seit einigen Jahren gibt es neben den manuell zu beladenden Injektoren auch sogenannte Preloaded-Systeme. Durch das Entfallen der manuellen Beladung sollen Risiken wie falsches Einlegen, Faltung oder Beschädigung während der Vorbereitung verhindert werden [1]. Eine mögliche Kontamination durch Berührung im OP-Umfeld wird ausgeschlossen.…”