2013
DOI: 10.1109/tasc.2012.2231714
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Inductive and Resistive SFCL

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
26
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 44 publications
(26 citation statements)
references
References 7 publications
0
26
0
Order By: Relevance
“…First, the RMS (Root Mean Square) of the voltage (V rms ) and the current (I rms ) was calculated by using (2) and (3), because the measured signals are not perfect sine wave. The apparent electric power (P a ) was then calculated by using (4).…”
Section: Analysis Of the Experimental Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…First, the RMS (Root Mean Square) of the voltage (V rms ) and the current (I rms ) was calculated by using (2) and (3), because the measured signals are not perfect sine wave. The apparent electric power (P a ) was then calculated by using (4).…”
Section: Analysis Of the Experimental Resultsmentioning
confidence: 99%
“…To reduce the fault current, various types of SFCLs (Superconductor Fault Current Limiters) have been considered [3]. The SFCL requires high voltage insulation, and large heat generation is accompanied by a restricted space to limit the fault current [4].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The SFCL responds before the first cycle peak and provides effective means to limit excessive fault currents to safe levels without the disadvantages of conventional fault current mitigation methods. Present researches on fault current limiters focus on resistive type [2] and inductive type [3][4][5][6][7][8][9][10][11]. The drawback of the concept of inductive limiter with shielded core was insertion of a finite impedance in the line even during normal operation, and the large size and weight of the iron core [7,10].…”
Section: Introductionmentioning
confidence: 99%
“…During fault condition, the resistance of the secondary winding is reflected in the system, which helps to limit the fault current. 27,28 For solid-state FCL application power semiconductor devices such as insulated-gate bipolar transistor (IGBT), silicon-controlled rectifier (SCR), and gate turn-off thyristor (GTO) are implemented in the DFIG system to get high-blocking voltage, lowconduction loss, and relative ease of control. Series switch, bridge, and resonant types are the classification of solid-state FCL.…”
mentioning
confidence: 99%