1998
DOI: 10.1177/03635465980260061301
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Initial Fixation Strength Between Biodegradable and Metallic Interference Screws and a Press-Fit Fixation Technique in a Porcine Model

Abstract: The objective of this study was to evaluate the initial fixation strength of a biodegradable interference screw compared with press-fit fixation and a titanium interference screw in anterior cruciate ligament reconstruction using a bone-patellar tendon-bone graft. Porcine lower limbs were used. The specimens underwent 500 loading cycles between 60 and 250 N. This corresponds to loads in the graft during aggressive rehabilitation. Thereafter, intact specimens were loaded to failure. Failure mode was defined by … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

8
102
3
2

Year Published

2003
2003
2022
2022

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 127 publications
(115 citation statements)
references
References 20 publications
8
102
3
2
Order By: Relevance
“…The rate of bone removal and deposition of the trabecular and cortical bone is also similar to that observed in humans (Mosekilde et al, 1993b). A porcine model has also been used to evaluate the initial fixation strength of a biodegradable interference screw in Litten-Brown, Corson and Clarke anterior cruciate ligament reconstruction using a bone-patellar tendon-bone graft (Seil et al, 1998;Walsh et al, 2009).…”
Section: Bonesmentioning
confidence: 67%
“…The rate of bone removal and deposition of the trabecular and cortical bone is also similar to that observed in humans (Mosekilde et al, 1993b). A porcine model has also been used to evaluate the initial fixation strength of a biodegradable interference screw in Litten-Brown, Corson and Clarke anterior cruciate ligament reconstruction using a bone-patellar tendon-bone graft (Seil et al, 1998;Walsh et al, 2009).…”
Section: Bonesmentioning
confidence: 67%
“…12,37,38 . In comparative works the bioabsorbable and the metallic screw sometimes come from different manufacturer, thus ensuring different geometry 32,33,34,35 . Most times only screw diameter and maybe the length match between the two screws, thread depths and profi le, head size, tine differ 32,33 .…”
Section: Discussionmentioning
confidence: 99%
“…Since both metallic and biomaterial used in orthopedic implants are stronger than cancellous bone the pull-out strength for identically shaped screws inserted with the same anatomical attributes (gap size, bone block cross-sectional shape, screw dimensions), should be similar 32 . The majority of original and review works show that bioabsorbable and metallic screws have similar failure loads 33,34,35 . Only a smaller number of works indicate that one screw is better than the other.…”
Section: Original Articlesmentioning
confidence: 99%
“…Many reports concerning cyst formation, tunnel enlargement, inflammatory reactions and mechanical failures have been published [3,19,20,22,23]. Doubts still exist about whether PLLA degrades completely at all [16].…”
Section: Discussionmentioning
confidence: 99%