2008
DOI: 10.1365/s10337-008-0579-5
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of LC and UPLC Coupled to MS–MS for the Determination of Sulfonamides in Egg and Honey

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(8 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…Some authors compared the performance of HPLC-MS/MS and UHPLC-MS/MS, obtaining narrower peaks and better chromatographic resolution using UHPLC-MS/MS, with separation of 10 sulfonamides in less than 20 min [48], although shorter running times can be achieved (<10 min) [8].…”
Section: Veterinary Drugsmentioning
confidence: 99%
“…Some authors compared the performance of HPLC-MS/MS and UHPLC-MS/MS, obtaining narrower peaks and better chromatographic resolution using UHPLC-MS/MS, with separation of 10 sulfonamides in less than 20 min [48], although shorter running times can be achieved (<10 min) [8].…”
Section: Veterinary Drugsmentioning
confidence: 99%
“…The sample matrix was defined as the leading factor. As secondary factors which might influence the analysis, the operator, the SPE cartridge, the storage period of the extracts, and the extract evaporation temperature were chosen [27]. Four concentration levels for each analyte were used in the validation study (Table 3).…”
Section: Analytical Performancementioning
confidence: 99%
“…The liquid-liquid extraction (LLE) (Anderson et al, 2005) and solid-phase extraction (SPE) (Pailler et al, 2009) have been extensively applied to the pretreatment of liquid food samples. However, most of these methods are time consuming and usually toxic due to the use of organic solvents (Yang et al, 2014).…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, analysis by liquid chromatography followed by fluorescence or ultra-violet detection systems can give low detection limits (Maudens et al, 2004;Pang et al, 2003;Posyniak et al, 2003;Sheridan et al, 2008) Recently, the basic advances in developing sensitivity and specifity of food analyses of pharmaceutical residues are due to the novel technology instrument, the application of ultra-performance liquid chromatography with tandem mass spectrometric detection (UPLC-MS/MS), which is more sophisticated technique allows a very effective isolation of analyte ions from the noise-producing matrix. The UPLC-MS/MS produces a high speed of analysis, greater resolution, higher peak capacity and sensitivity (Swartz 2005;Tamošiūnas & Padarauskas, 2008).…”
Section: Introductionmentioning
confidence: 99%