2022
DOI: 10.1080/14779072.2022.2043745
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of left atrial appendage parameters using computed tomography vs. transesophageal echocardiography for watchman device implantation: a systematic review & meta-analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 26 publications
0
4
0
1
Order By: Relevance
“…Procedure planning is the key to minimize the risk of peri‐device leak or device‐related thrombosis. Recent studies suggested that CT‐guided procedure planning for the LAAC helped understanding of three‐dimensional LAA anatomy and provided accurate sizing of the LAA and higher procedural success as compared to TEE alone 2,3 …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Procedure planning is the key to minimize the risk of peri‐device leak or device‐related thrombosis. Recent studies suggested that CT‐guided procedure planning for the LAAC helped understanding of three‐dimensional LAA anatomy and provided accurate sizing of the LAA and higher procedural success as compared to TEE alone 2,3 …”
Section: Discussionmentioning
confidence: 99%
“…three-dimensional LAA anatomy and provided accurate sizing of the LAA and higher procedural success as compared to TEE alone. 2,3 On retrospective review of CT, the initial 24 mm Watchman device seemed too small for the LAA anatomy. Implantation of larger Watchman device in more proximal part of LAA would have resulted in complete sealing of LAA without peri-device leak.…”
Section: Discussionmentioning
confidence: 99%
“…По результатам метаанализа Y. Sattar и соавт., КТ по сравнению с ЧпЭхоКГ привела к увеличению размеров устья УЛП, повышению вероятности прогнозирования правильного размера устройства и сокращению времени рентгеноскопии у пациентов, перенёсших окклюзию УЛП с помощью устройства WATCHMAN. Не было никаких существенных различий в других процедурных исходах [35].…”
Section: принятые сокращенияunclassified
“…However, cardiac computed tomography (CT) is used increasingly for pre-procedural imaging. Data indicate that it might lead to more successful device implantations than a TEE-guided strategy [ 7 , 11 , 12 ]. Moreover, CT can be used for printing of patient-specific 3D-models of the LAA or simulation of implant result [ 13 ].…”
Section: Introductionmentioning
confidence: 99%