2022
DOI: 10.4317/jced.59343
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of marginal microleakage of metal copings cemented with three luting cements

Abstract: Background To evaluate the marginal microleakage in single metal copings cemented with zinc phosphate, glass ionomer, and resin-modified ionomer. Material and Methods An experimental in vitro study was carried out. The calculation of the sample was determined using the G*Power software; 15 premolars were considered per group. The teeth were carved considering a preparation with a chamfer-type shoulder with an angulation of 6°. Working models were obtained, where the met… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

1
1
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 21 publications
1
1
0
Order By: Relevance
“…The resin-reinforced GIC group had more microleakage than self-adhesive resin cement group, both in ideal and contaminated conditions. This result of our study was in agreement with the study of Vargas et al [11] and Ebadian et al [21]. Ebadian et al studied the microleakage of restorations cemented with RelyX™ Ultimate, RelyX™ Unicem, GC Gold Label, and Hoffmann cements, finding that Hoffmann zinc phosphate cement obtained higher microleakage values (5.00 ± 2.000 mm) followed by GC Gold Label glass ionomer cement (2.71 ± 1.976 mm) and finally by the resinous cements RelyX™ Unicem (2.14 ± 1.952 mm) and RelyX™ Ultimate (0.86 ± 1.215 mm).…”
Section: Discussionsupporting
confidence: 95%
See 1 more Smart Citation
“…The resin-reinforced GIC group had more microleakage than self-adhesive resin cement group, both in ideal and contaminated conditions. This result of our study was in agreement with the study of Vargas et al [11] and Ebadian et al [21]. Ebadian et al studied the microleakage of restorations cemented with RelyX™ Ultimate, RelyX™ Unicem, GC Gold Label, and Hoffmann cements, finding that Hoffmann zinc phosphate cement obtained higher microleakage values (5.00 ± 2.000 mm) followed by GC Gold Label glass ionomer cement (2.71 ± 1.976 mm) and finally by the resinous cements RelyX™ Unicem (2.14 ± 1.952 mm) and RelyX™ Ultimate (0.86 ± 1.215 mm).…”
Section: Discussionsupporting
confidence: 95%
“…However, the problem in this cement is its high solubility and susceptibility to moisture if exposed to moisture during the initial setting period. To overcome the problems of solubility and lack of adhesion, newer resin cements have been introduced [11,12]. However, a high coefficient of thermal expansion and hence polymerization shrinkage are major concerns with these resins containing luting agents.…”
Section: Introductionmentioning
confidence: 99%