2007
DOI: 10.2320/matertrans.maw200708
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of Mechanical Properties of Thin Copper Films Processed by Electrodeposition and Rolling

Abstract: Thin copper films with grain sizes of 31 nm and 3.3 mm were processed by electrodeposition, and their mechanical properties were compared with those of a rolled copper film. The hardness and strength for the electrodeposited copper with a grain size of 3.3 mm were lower than those of the rolled copper with a grain size of 6.3 mm, however, the elongation to failure for the former was larger than that for the latter. Intense (111) texture formation was found for the rolled copper. Therefore, it is suggested that… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 21 publications
0
2
1
Order By: Relevance
“…Actually, although thiourea was used, the grain sizes of the present electrodeposited copper (³4 µm) were larger than those reported in the previous studies, 10,11) which perhaps comes from the fact that the current density during the electrodeposition joining was much smaller than applied in those literatures. Future studies will therefore focus on suppressing grain coarsening.…”
Section: Alcontrasting
confidence: 57%
See 1 more Smart Citation
“…Actually, although thiourea was used, the grain sizes of the present electrodeposited copper (³4 µm) were larger than those reported in the previous studies, 10,11) which perhaps comes from the fact that the current density during the electrodeposition joining was much smaller than applied in those literatures. Future studies will therefore focus on suppressing grain coarsening.…”
Section: Alcontrasting
confidence: 57%
“…Adding thiourea to the electroplating bath increased the join strength to 214 MPa, which may be due to grain refinement in the electrodeposited copper. 10,11) As described later, the sample joined by Cu electrodeposition in the bath with thiourea fractured at the center of the electrodeposited Cu, while those joined without thiourea showed the fracture at the Al/Cu interface. The SEM image and crystallographic microstructure of the copper joint electrodeposited in the electrolyte containing thiourea are shown in Fig.…”
Section: Al Alloy Sheetmentioning
confidence: 75%
“…In many cases measurements are necessary to accurately characterize their mechanical, thermal and/or electrical properties. This is particularly important for new materials, but also for well-known materials like copper, whose properties may depend on their processing [5,6]. For instance, to simulate the thermomechanical behaviour of solder joints in surface mount assemblies, elastic, plastic and creep properties of the solder are necessary.…”
Section: Methodology For Predictive Reliabilitymentioning
confidence: 99%