Comparison of multi-frequency bioimpedance with perometry for the early detection and intervention of lymphoedema after axillary node clearance for breast cancer

Abstract: The importance of early detection of lymphoedema by arm volume measurements before surgery and repeated measurements after surgery in women undergoing axillary node clearance (ANC) in order to enable early intervention is recognised. A prospective multi-centre study was performed which studied the difference between multi-frequency bioimpedance electrical analysis (BIS) and perometer arm measurement in predicting the development of lymphoedema. Women undergoing ANC underwent pre-operative and regular post-oper… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
50
0
1

Year Published

2015
2015
2019
2019

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(56 citation statements)
references
References 25 publications
1
50
0
1
Order By: Relevance
“…As previous diagnosis of LE does not guarantee continued presence of LE, it is not an appropriate reference standard. Other studies have evaluated diagnostic thresholds using measurement tools, such as water displacement or BIS, with nonvalidated thresholds as the reference standard [18,19]. In contrast, the present study employed lymphoscintigraphy imaging as the reference standard.…”
Section: Discussionmentioning
confidence: 99%
“…As previous diagnosis of LE does not guarantee continued presence of LE, it is not an appropriate reference standard. Other studies have evaluated diagnostic thresholds using measurement tools, such as water displacement or BIS, with nonvalidated thresholds as the reference standard [18,19]. In contrast, the present study employed lymphoscintigraphy imaging as the reference standard.…”
Section: Discussionmentioning
confidence: 99%
“…Concurrent validity has been studied using a variety of assessment methods involving both clinical and research models of BIA devices. Moderate to strong correlations have been reported between BIA data and both self-report ( r = 0.71, research model46) and perometry results ( r = 0.71-0.93, research model34,42,43,47; r = 0.40-0.60, clinical model48). Correlation with circumferential measurement ranged from low (clinical model)49 to moderate (0.31-0.52, research model,50 clinical model41).…”
Section: Bioimpedance Analysismentioning
confidence: 98%
“…Alternatively, the clinician may use perometry or multifrequency bioimpedance measurements, which are automated LV scanning methods that eliminate interobserver variability, but these are more expensive. Comparison between these LV measurement methods shows that the use of a tape measure for early diagnosis of lymphedema in patients is effective, but the sensitivity of this technique leads to some uncertainty (186). …”
Section: Impaired Lymphatic Function In Lymphedemamentioning
confidence: 99%